Toro TEMPUS-AG-MS
6
Temperature sensor Input
(PT100 Standard)
Temperature sensor (S4 only)
The
orange wire
(+ Symbol) of your TEMPUS-AG-MS
must be connected to one of the two
red wires
of
the temperature sensor
The
orange wire
(- Symbol) of your TEMPUS-AG-MS
must be connected to the white wire of
the temperature sensor
Note: the Tempus AG S1 doesn't have temperature sensor input.
Temper
atur
e
Configurable sensor inputs (3 for S4, 1 for S1)
Types of sensors that can be connected:
• Dry contact (rain sensor, wind sensor, ...)
• Pulse (flowmeter, wind sensor, ...)
• Analog (0-3.5V) (moisture sensor, solar radiation ...)
The
black wire
(- Symbol) of your TEMPUS-AG-MS
must be connected to the
gray wire
of the VH400
moisture sensor
The
yellow wire
(+ Symbol) of your TEMPUS-AG-MS
must be connected to the
black wire
of the VH400
moisture sensor
The
red wire
(lampo Symbol) of your TEMPUS-AG-MS
must be connected to the
red wire
of the VH400
moisture sensor
Moistur
e Sensor
Note: the Tempus AG S1 has only one configurable sensor input.
Example of connecting an analog input sensor:
VH400 moisture sensor