Connecting the Valve

The TBC

TM

WP controller can only operate valves equipped with a DC Latching solenoid. Verify 

that the device being controlled is equipped with the proper solenoid.

Connecting the Valves
Step 1 – 

If connecting more than one valve, 
determine the station designation 
for each valve. For programming 
purposes, note the zone that each 
valve/station will service. 

Step 2 – 

Connect the TBC

TM

WP controller’s 

station 1 wire to the positive (red) 
wire lead from Station 1 solenoid. 
Connect the TBC

TM

WP controller’s 

C (common) wire (black) to the 
negative (black) solenoid wire. 
Connect the remaining Station 
wires (colored) to their respected 
soleoid wires in the same manner.

 

NOTE:

 

Use water sealed/

proof wire connectors (not 
supplied) for this application.

Step 3 – 

Check the valve(s) and controller for proper operation. (Refer to TBC

TM

HH User’s 

Guide for operation.)

Station 1

Station    Wire Color
     1         Red
     2         Orange
     3         Gray
     4         Green
     5         Blue
     6         Brown

Station 2

Station 3

Содержание TBC WP

Страница 1: ...s Two 9 Volt Batteries Not Included Operates DC Latching Solenoids Sensor Compatible Non Volatile Memory Operate Valves Up to 200ft 61m When Using 18 AWG Integrated Infrared Interface With Optional In...

Страница 2: ...t AWG 18 1 0mm2 Multi Strand Wire 200ft 61m AWG 16 1 5mm2 Multi Strand Wire 305ft 100m AWG 14 2 5mm2 Multi Strand Wire 500ft 150m AWG 12 4 0mm2 Multi Strand Wire 820ft 250m TBCTM WP Station Output Pow...

Страница 3: ...s of irrigation run time per station Day of the week 31 day interval Odd and Even watering schedules with day exclusions 0 300 monthly water budgeting in 10 increments Manual semi auto or auto activat...

Страница 4: ...solenoid and unscrew it from the valve Step 3 Install the DC Latching solenoid onto the valve Step 4 Strip approximately 1 2 1 25 cm of the insulation from the DC Latching solenoid s wires Step 5 Ref...

Страница 5: ...tep 2 Connect the TBCTM WP controller s station 1 wire to the positive red wire lead from Station 1 solenoid Connect the TBCTM WP controller s C common wire black to the negative black solenoid wire C...

Страница 6: ...ontroller Step 2 Cut the wire loop yellow from TBCTM WP controller s Sensor A and B Strip approximately 1 2 1 25 cm of insulation from the wires and connect them to the rain sensor wires Wire polarity...

Страница 7: ...nscrew the battery cap to access the battery compartment Step 2 Install two 9 VDC alkaline batteries onto the two battery connectors located inside the compartment IMPORTANT Make sure no water is pres...

Страница 8: ...box Step 2 Secure the two mounting screws on the marked location Leave approximately 1 4 6mm of the exposed screw Step 3 Hang the controller onto the screws Verify that the screws are seated properly...

Страница 9: ...the batteries are connected properly Possible Cause The TBCTM WP controller IR port is dirty Solution Clean the TBCTM WP IR port Possible Cause Improper connection between hand held and controller So...

Страница 10: ...y proper operation of that sensor Possible Cause Short circuit in the solenoid or the wiring to the solenoid Solution Verify with TBCTM WP Programmer that a short was detected on the station If a shor...

Страница 11: ...ed in any manner contrary to Toro s specifications and instructions nor where equipment is altered or modified Neither The Toro Company nor Toro Warranty Company is liable for indirect incidental or c...

Страница 12: ...be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the irrigat...

Отзывы: