correct K Value.

Off_s

: Review your flow sensor’s documentation for its 

correct Offset value.

PPG

 (if Bermad selected): Pulse per gallon based on flow 

meter wiring. See your Bermad flow meter documentation 

for proper setting.

Rain Bucket Configuration

Tip

: The amount of water per tip. The typical rain bucket 

might have a tip point of 0.01”. Check your rain bucket’s 

documentation for correct tip point.

Max

: This is the limit at which the alarm will trip. If the 

Tip unit is 0.01 inch, and the Max limit is 1 inch, it would 

take 100 tips (within the R_win window) to trigger the 

alarm.

Unit

: Select either English or Metric for display of rain 

bucket data in either inches or millimeters.

Alarm

: On or Off. Turn on the alarm 

R_win

: Set the period of time (as a moving window) 

that the controller will calculate rain bucket tips towards 

reaching the max limit.

Act

: If an alarm is triggered, this is the Action that the 

controller will take. Possible choices are:

•  None

. The alarm will only alert the operator.

•  Start Station

. Starts a specified station.

•  Cancel Station

. Cancels a specified station.

•  Cancel All

. Cancels all irrigation activity.

•  Rain Hold

. Places a rain hold on the controller for a 

specified number of days.

Count

: The number of times the rain bucket has filled and 

“tipped”, independent of Alarm status and R_Win setting.

Hr

: Possible to go back in hour increments to review the 

number of tips during that hour from the current time.

H_Cnt

: The number of tips in that hour.

Total

: The number of times the rain bucket has filled and 

“tipped” in the rain window (R_win above) only when the 

alarm is set to On.

Status Sensor Configuration

Sw

: Normally Closed or Normally Open.  

Select the correct setting for your sensor.

Alarm

: Turn the alarm On or Off for the sensor.

QTime

: Qualification time. How long does the alarm 

condition (normally closed becoming open, for example) 

have to stay in that condition for the alarm to be triggered. 

RTime

: Reset time. Clears the alarm automactially if alarm 

condition no longer exists for that period of time.

Act

: If an alarm is triggered, this is the Action that the 

controller will take. Possible choices are:

•  None

. The alarm will only alert the operator.

•  Start Station

. Starts a specified station.

•  Cancel Station

. Cancels a specified station.

•  Cancel All

. Cancels all irrigation activity.

•  Rain Hold

. Places a rain hold on the controller for a 

specified number of days.

Input : 3   Typ:RAIN

Tip   : 0.01 in

Max   : 01.00 in

Unit  : English (in) 

Alarm : On 

R_win : 24hr 

Act   : Rain Hold

Hold  : 02days

Count : 4

Hr: 02 H_Cnt:00001 

Input : 4   Typ:STAT

Sw    : Norm Close

Alarm : On 

QTime : 10s 

RTime : 01m

Act   : Cancel All

Содержание SIK

Страница 1: ...als Terminal Description IN 1 Pressure Sensor Input IN 2 Flow Rain or Status Sensor Input IN 3 Flow Rain or Status Sensor Input IN 4 Flow Rain or Status Sensor Input IN 5 Flow Rain or Status Sensor Input IN 6 Flow Rain or Status Sensor Input COM 12 V Ground or Common 12V 12 V DC Output The Sensor Input Kit receives sensor data from status flow temperature rain buckets and pressure sensors then rel...

Страница 2: ...the satellite controller and check for proper operation 3 2 1 4 Figure 1 5 A B 6 Timing Module sold separately Installation The Sensor Input Board only works with the new Timing Module TM right included with the sensor input board bundle VP SEN BUNDLE or purchased separately 118 5487SK If your controller still uses the old TM you must purchase the new TM to take advantage of the VP Sensor Input Ki...

Страница 3: ...tem and cables already run to the controller For all sensor installation procedures turn off or remove power from the controller Pressure Sensor Toro sells a pressure sensor kit part number PRESS200 SEN KIT composed of a 6 long sensor cable and a pressure sensor Steps 1 At the sensor terminal board secure the pressure sensor s black lead to screw IN 1 and white lead to screw 12V see Terminals Expl...

Страница 4: ...ermitted for operation Max Maximum pressure permitted for operation Unit Select English or Metric for display of pressure in pounds per square inch psi or bar Alarm Select either a high limit alarm Hi and or a low limit alarm Lo In the Set field it is possible to turn the Hi and Lo alarm On of Off QTime Qualification time How long does the alarm condition max pressure exceeded for example have to ...

Страница 5: ...Set a time when irrigation is no longer permitted I_Min For standalone Minimum flow rate allowed at the beginning of the water window I_Max Paired with I_Min Maximum flow rate allowed during the water window O_Max Maximum flow rate allowed outside of water window One might typically set this value rather low to help detect valve or sprinkler leaks Unit Select either English or Metric for display o...

Страница 6: ...ber of days Count The number of times the rain bucket has filled and tipped independent of Alarm status and R_Win setting Hr Possible to go back in hour increments to review the number of tips during that hour from the current time H_Cnt The number of tips in that hour Total The number of times the rain bucket has filled and tipped in the rain window R_win above only when the alarm is set to On St...

Страница 7: ...n 2 Down arrow to Reset SIB s 3 to change to Yes All 4 There is a confirmation screen Press the Stop button to cancel the reset Firmware Update A handful of satellites will need a firmware update to take advantage of the Lynx Smart Satellite Sensor Kit Check your satellite s firmware 1 Press the Diagnostic button 2 Turn the Command dial to Revision 3 Check Revision number If firmware revision is l...

Страница 8: ...h type of sensor installed with minimum and maximum values set 5 Remember a sensor input board takes up 8 stations We have to tell Lynx that the correct satellite from step 2 now has 8 fewer stations Click on Control System find the desired satellite and enter the correct number of stations Figure 2 6 Click Alarm Response to set up alarm conditions for the various sensors 7 Select the desired sens...

Страница 9: ... Sensor Input Board to monitor You will see a screen similar to Figure 4 though the number and type of sensors might be different as well as the ranges for the sensors Historic Click Report Generator then Sensors Select the desired sensor the date range and whether to view the sensor data as a table Figure 5 or graph Figure 6 Figure 4 Figure 5 Figure 6 ...

Страница 10: ... that may cause undesirable operation This equipment generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instruction may cause interference to radio and television reception It has been type tested and found to comply with the limits for a FCC Class B computing device in accordance with the specification in subpart J...

Отзывы: