Sensor Input Board Installation

1.  Remove the front panel door and power 

down the satellite controller.

2.  Locate an available output board slot to 

install the sensor input board. If the satellite 

is utilizing all output board slots, remove 

the last station output board and use that 

location.

The empty slot might end up being on 

the back side of the controller.
If there are multiple empty slots 

available, the sensor input board 

must be

 

installed in the 

first available slot

 after the 

station output boards.

3.  Install the sensor input board 

A

 and secure 

it with the retaining screw 

1

 and panhead 

screw 

2

.

4.  Install the ribbon cable 

3

 from the 

distribution board to the sensor input board. 

Front installation: Use the short cable. 

Rear installation: Use the longer cable.

5.  Install the fuse 

4

.

6.  If a Surge Board is not already available, 

install the provided Surge board 

B

.  

Secure with three retaining screws 

5

.  

Install two panhead screws 

6

 into Surge 

board for proper grounding.

7.  Restore power to the satellite controller and 

check for proper operation.

3

2

1

4

Figure 1

5

A

B

6

Timing Module (sold separately) Installation

The Sensor Input Board only works with the new Timing 

Module (TM, right) included with the sensor input board 

bundle (VP-SEN-BUNDLE) or purchased separately  

(118-5487SK). If your controller still uses the old TM, you 

must purchase the new TM to take advantage of the VP 

Sensor Input Kit.
Installers must either purchase the Service Kit #118-

5487SK or already have the 118-5487 TM hardware.

Satellite may reset to default settings upon updating 

the firmware version.

Remove the old TM:

1.  Open the lid of the pedestal.

2.  Unscrew the four screws 

1

 that secure the timing 

module into the pedestal.

3.  Remove the TM and unplug the two ribbon cables 

2

.

4.  If there is a modem attached, disconnect the ribbon 

cable to that as well. 

Install the new TM:

1.  Plug the two ribbon cables from step 3 above into the 

new TM.

2.  If there is a modem attached, plug that in.

3.  Set TM into the pedestal and secure with the four 

screws. 

+

HOME

%ADJUST

START

PAUSE/

RESUME

STOP

SYSTEM

SETTINGS

MANUAL

WATERING

SCHEDULED

WATERING

DIAGNOSTICS

STATION

SETTINGS

Mode

Central       Local          Off

1

1

1

1

2

The new Timing Module (TM)

Содержание SIK

Страница 1: ...als Terminal Description IN 1 Pressure Sensor Input IN 2 Flow Rain or Status Sensor Input IN 3 Flow Rain or Status Sensor Input IN 4 Flow Rain or Status Sensor Input IN 5 Flow Rain or Status Sensor Input IN 6 Flow Rain or Status Sensor Input COM 12 V Ground or Common 12V 12 V DC Output The Sensor Input Kit receives sensor data from status flow temperature rain buckets and pressure sensors then rel...

Страница 2: ...the satellite controller and check for proper operation 3 2 1 4 Figure 1 5 A B 6 Timing Module sold separately Installation The Sensor Input Board only works with the new Timing Module TM right included with the sensor input board bundle VP SEN BUNDLE or purchased separately 118 5487SK If your controller still uses the old TM you must purchase the new TM to take advantage of the VP Sensor Input Ki...

Страница 3: ...tem and cables already run to the controller For all sensor installation procedures turn off or remove power from the controller Pressure Sensor Toro sells a pressure sensor kit part number PRESS200 SEN KIT composed of a 6 long sensor cable and a pressure sensor Steps 1 At the sensor terminal board secure the pressure sensor s black lead to screw IN 1 and white lead to screw 12V see Terminals Expl...

Страница 4: ...ermitted for operation Max Maximum pressure permitted for operation Unit Select English or Metric for display of pressure in pounds per square inch psi or bar Alarm Select either a high limit alarm Hi and or a low limit alarm Lo In the Set field it is possible to turn the Hi and Lo alarm On of Off QTime Qualification time How long does the alarm condition max pressure exceeded for example have to ...

Страница 5: ...Set a time when irrigation is no longer permitted I_Min For standalone Minimum flow rate allowed at the beginning of the water window I_Max Paired with I_Min Maximum flow rate allowed during the water window O_Max Maximum flow rate allowed outside of water window One might typically set this value rather low to help detect valve or sprinkler leaks Unit Select either English or Metric for display o...

Страница 6: ...ber of days Count The number of times the rain bucket has filled and tipped independent of Alarm status and R_Win setting Hr Possible to go back in hour increments to review the number of tips during that hour from the current time H_Cnt The number of tips in that hour Total The number of times the rain bucket has filled and tipped in the rain window R_win above only when the alarm is set to On St...

Страница 7: ...n 2 Down arrow to Reset SIB s 3 to change to Yes All 4 There is a confirmation screen Press the Stop button to cancel the reset Firmware Update A handful of satellites will need a firmware update to take advantage of the Lynx Smart Satellite Sensor Kit Check your satellite s firmware 1 Press the Diagnostic button 2 Turn the Command dial to Revision 3 Check Revision number If firmware revision is l...

Страница 8: ...h type of sensor installed with minimum and maximum values set 5 Remember a sensor input board takes up 8 stations We have to tell Lynx that the correct satellite from step 2 now has 8 fewer stations Click on Control System find the desired satellite and enter the correct number of stations Figure 2 6 Click Alarm Response to set up alarm conditions for the various sensors 7 Select the desired sens...

Страница 9: ... Sensor Input Board to monitor You will see a screen similar to Figure 4 though the number and type of sensors might be different as well as the ranges for the sensors Historic Click Report Generator then Sensors Select the desired sensor the date range and whether to view the sensor data as a table Figure 5 or graph Figure 6 Figure 4 Figure 5 Figure 6 ...

Страница 10: ... that may cause undesirable operation This equipment generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instruction may cause interference to radio and television reception It has been type tested and found to comply with the limits for a FCC Class B computing device in accordance with the specification in subpart J...

Отзывы: