Relays with 4 Terminals
g230518
Figure 256
1.
Kubota diesel relays
4.
Main power relay
2.
Yanmar diesel relays
5.
Glow relay
3.
Kubota gas relays
A number of electrical relays that have 4 terminals are used in the machine
electrical system. A tag near the wire harness relay connector can be used
to identify each relay.
The main power relay is used to provide current to the operator seat, InfoCenter,
TEC, headlights, power point, and optional electric equipment. When the key
switch is in the R
UN
or S
TART
position, the main power relay is energized.
The glow relay is used on machines with a Kubota or Yanmar diesel engine to
provide current to the engine glow plugs. On machines with a Kubota diesel
engine, the glow relay is energized by the TEC. The glow relay is energized by
the engine ECU on machines with a Yanmar diesel engine.
The main power and glow relay are attached to a frame bracket under the hood
next to the hydraulic pump driveshaft (
).
Note:
A fault code may be displayed on the InfoCenter display if the main power
relay, glow relay or circuit wiring is damaged.
Testing the Relays with 4 Terminals
1. Park the machine on a level surface, lower the cutting units, shut off the
engine, set the parking brake, and remove the key from the key switch.
2. Open the hood to get access to the relays. Remove the hood saddle from
the machine for easier access to relay.
3. To ensure that the machine operation does not occur unexpectedly,
disconnect the negative (-) cable from the battery and then disconnect the
Electrical System: Testing the Electrical Components
Page 7–88
Reelmaster
®
5410/5510/5610 Series
15216SL Rev C
Содержание Reelmaster 5510 Series
Страница 4: ...NOTES NOTES Page 4 Reelmaster 5410 5510 5610 Series 15216SL Rev C...
Страница 10: ...Preface Page 10 Reelmaster 5410 5510 5610 Series 15216SL Rev C...
Страница 18: ...Safety Safety and Instructional Decals Page 1 8 Reelmaster 5410 5510 5610 Series 15216SL Rev C...
Страница 118: ...Kubota Gasoline Engine Service and Repairs Page 5 26 Reelmaster 5410 5510 5610 Series 15216SL Rev C...
Страница 136: ...g230013 Figure 64 Hydraulic System Hydraulic Schematics Page 6 18 Reelmaster 5410 5510 5610 Series 15216SL Rev C...
Страница 137: ...g213698 Figure 65 Reelmaster 5410 5510 5610 Series Page 6 19 Hydraulic System Hydraulic Schematics 15216SL Rev C...
Страница 356: ...Hydraulic System Service and Repairs Page 6 238 Reelmaster 5410 5510 5610 Series 15216SL Rev C...
Страница 366: ...g213684 Figure 198 Electrical System InfoCenter Display Page 7 10 Reelmaster 5410 5510 5610 Series 15216SL Rev C...
Страница 488: ...Electrical System Service and Repairs Page 7 132 Reelmaster 5410 5510 5610 Series 15216SL Rev C...
Страница 594: ...Cutting Unit Service and Repairs Page 9 64 Reelmaster 5410 5510 5610 Series 15216SL Rev C...
Страница 620: ...Belt Driven Groomer Optional Service and Repairs Page 10 26 Reelmaster 5410 5510 5610 Series 15216SL Rev C...
Страница 640: ...Universal Groomer Optional Service and Repairs Page 11 20 Reelmaster 5410 5510 5610 Series 15216SL Rev C...
Страница 650: ...Page A 10 15216SL Rev C Reelmaster All Models Drawing 120 6356 Rev D Sheet 1 of 2 Wire Harness Drawing Main g219150...
Страница 651: ...Reelmaster All Models Drawing 120 6356 Rev D Sheet 2 of 2 15216SL Rev C Page A 11 Wire Harness Drawing Main g219151...
Страница 652: ...Page A 12 15216SL Rev C Reelmaster All Models Drawing 115 8081 Rev C Sheet 1 of 2 Wire Harness Drawing Seat g219152...
Страница 653: ...Reelmaster All Models Drawing 115 80812 Rev C Sheet 2 of 2 15216SL Rev C Page A 13 Wire Harness Drawing Seat g219153...
Страница 662: ......