Charging
To minimize possible damage to the battery and allow
the battery to be fully charged, the slow charging meth-
od is presented here. This charging method can be ac-
complished with a constant current battery charger
which is available in most shops.
CAUTION
instructions
when using a battery charging.
Follow the manufacturer’s
1.
Determine the battery charge level from either its
open circuit voltage or specific gravity.
Battery Charge
Level
Open Circuit
Voltage
Specific
Gravity
100%
12.68
1.265
75%
12.45
1.225
50%
12.24
1.190
25%
12.06
1.155
0%
11.89
1.120
CAUTION
Do not charge a frozen battery because it
tery warm to 60
_
F (15.5
_
C) before con-
Charge the battery in a well–ventilated
charging. These gases are explosive;
Nausea may result if the gases are in-
haled. Unplug the charger from the elec-
trical outlet before connecting or discon-
necting the charger leads from the battery
posts.
can explode and cause injury. Let the bat-
necting to a charger.
place to dissipate gases produced from
keep open flame and electrical spark
away from the battery. Do not smoke.
3. Following the manufacturer’s instructions, con-
nect the charger cables to the battery. Make sure a good
connection is made.
4. Charge the battery following the manufacturer’s
instructions.
2. Determine the charging time and rate using the
manufacturer’s battery charger instructions or the
following table.
Reserve
Battery Charge Level
Capacity
(Percent of Fully Charged)
(Minutes)
(Minutes)
75%
50%
25%
0%
80 or less
3.8 hrs
7.5 hrs
11.3 hrs
15 hrs
@
@
@
@
3 amps
3 amps
3 amps
3 amps
81 to 125
5.3 hrs
10.5 hrs 15.8 hrs
21 hrs
@
@
@
@
4 amps
4 amps
4 amps
4 amps
126 to
5.5 hrs
11 hrs
16.5 hrs
22 hrs
170
@
@
@
@
5 amps
5 amps
5 amps
5 amps
171 to
5.8 hrs
11.5 hrs 17.3 hrs
23 hrs
250
@
@
@
@
6 amps
6 amps
6 amps
6 amps
above
6 hrs
12 hrs
18 hrs
24 hrs
250
@
@
@
@
10 amps 10 amps 10 amps 10 amps
5. Occasionally check the temperature of the battery
electrolyte. If the temperature exceeds 125
_
F (51.6
_
C)
or the electrolyte is violently gassing or spewing, the
charging rate must be lowered or temporarily stopped.
6. Three hours prior to the end of the charging, mea-
sure the specific gravity of a battery cell once per hour.
The battery is fully charged when the cells are gassing
freely at a low charging rate and there is less than a
0.003 change in specific gravity for three consecutive
readings.
Electrical
System
Reelmaster 2300–D/2600–D
Page 5 – 29
Electrical System
Содержание REELMASTER 2300-D
Страница 2: ...This page is blank ...
Страница 4: ...This page is blank ...
Страница 10: ...Safety Page 1 6 Reelmaster 2300 D 2600 D ...
Страница 12: ...Equivalents and Conversions Product Records and Manuals Page 2 2 Reelmaster 2300 D 2600 D ...
Страница 14: ...Maintenance Interval Chart Product Records and Manuals Page 2 4 Reelmaster 2300 D 2600 D ...
Страница 38: ...Engine Page 3 20 Reelmaster 2300 D 2600 D ...
Страница 158: ...Wheels and Brakes Page 6 8 Reelmaster 2300 D 2600 D ...
Страница 185: ...This page is blank ...
Страница 186: ...Commercial Products The Toro Company ...