![Toro ProLine 30165 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/toro/proline-30165/proline-30165_operators-manual_1131985026.webp)
Maintenance
24
Air Cleaner
Service Interval/Specification
Foam Element: Clean and re-oil after every 25
operating hours.
Paper Element: Replace after every 100 operating
hours.
Note:
Service the air cleaner more frequently
(every few hours) if operating
conditions are extremely dusty or
sandy.
Removing the Foam and Paper Elements
1.
Disengage the power take off (PTO), set the
parking brake, and turn the ignition key to
“OFF” to stop the engine. Remove the key.
2.
Clean around the air cleaner to prevent dirt from
getting into the engine and causing damage.
Unscrew the cover nuts and remove the air
cleaner cover (Fig. 17).
3.
Remove the air cleaner assembly (Fig. 17).
4.
Carefully slide the foam element off the paper
element (Fig. 17).
ÏÏÏÏÏ
ÏÏÏÏÏ
ÏÏÏÏÏ
ÏÏÏÏÏ
ÏÏÏÏ
ÏÏÏÏ
ÏÏÏÏ
1
2
2072
3
4
5
Figure 17
1.
Cover nut
2.
Air cleaner cover
3.
Foam element
4.
Paper element
5.
Air cleaner base
Cleaning the Foam and Paper Elements
1.
Foam Element
A.
Wash the foam element in liquid soap and
warm water. When the element is clean,
rinse it thoroughly.
B.
Dry the element by squeezing it in a clean
cloth.
C.
Put one or two ounces of oil on the element
(Fig. 18). Squeeze the element to distribute
the oil.
IMPORTANT: Replace the foam element if it
is torn or worn.
2
1213
1
Figure 18
1.
Foam element
2.
Oil