Use the
MASTER
-
BOOM
switch to stop the spray
flow before stopping the sprayer. Once stopped,
use the neutral engine speed lock to hold the
engine speed up to keep the agitation running.
•
You will obtain better results if the sprayer is
moving when you turn the booms on.
•
Watch for changes in the application rate that may
indicate that your speed has changed beyond the
range of the nozzles or there is a problem with the
spray system.
HD-Series Models with a Automatic Transmission
Operated in the Automatic Mode
Note:
Refer to the nozzle selection guide that is
available through your Authorized Toro Dealer.
•
If you are operating the sprayer at a slow ground
speed that causes the computer to maintain
too low of a sprayer system pressure for the
application rating of the selected nozzles, the
chemical solution will discharge from the nozzle
incorrectly (running or dribbling). Select a sprayer
nozzle with a lower application rate range.
•
If you are operating the sprayer at a high ground
speed that causes the computer to use full sprayer
system pressure and the sprayer pressure is
inadequate to achieve the desired application rate.
To correct you application rate, slow your ground
speed to achieve your application rate or select a
sprayer nozzle with a higher application rate range.
Unclogging a Nozzle
If a nozzle becomes clogged while you are spraying,
you can clean it using a hand spray bottle of water
or a toothbrush.
1.
Stop the sprayer on a level surface, stop the
engine, and set the parking brake.
2.
Set the master
BOOM
-
SWITCH
to the Off position
and then set the
PUMP
switch to the Off position.
3.
Remove the clogged nozzle and clean it using a
spray bottle of water or a toothbrush.
Selecting a Nozzle
Note:
Refer to the nozzle selection guide that is
available through your Authorized Toro Dealer.
The turret bodies can accept up to 3 different nozzles.
To select the desired nozzle:
1.
Stop the sprayer on a level surface, stop the
engine, and set the parking brake.
2.
Set the
MASTER
-
BOOM
switch to the Off position
and set the
PUMP
switch to the Off position.
3.
Rotate the turret of the nozzles in either direction
to the correct nozzle.
Cleaning the Sprayer
Important:
You must always empty and clean
the sprayer immediately after each use. Failure
to do so may cause the chemicals to dry or
thicken in the lines, clogging the pump and other
components.
Toro recommends using the approved rinse kit for
this machine. Contact your Authorized Toro Dealer
for more information.
Clean the spray system after
each
spraying session.
To properly clean the spray system:
•
Use three separate rinses.
•
Use the cleaners and neutralizers as
recommended by the chemical manufacturers.
•
Use pure clean water (no cleaners or neutralizers)
for the
last
rinse.
1.
Stop the sprayer, set the parking brake, and turn
off the engine.
2.
Locate the tank drain valve on the left side of
the machine (
g022364
Figure 72
1.
Tank-drain handle
3.
Open the valve to drain all unused material from
the tank(
).
Important:
Dispose of all waste chemicals
according to local codes and the material
manufacturer's instructions.
52
Содержание Multi Pro WM 41240
Страница 79: ...Schematics g255886 Flow Diagram Sprayer System DWG 125 0699 Rev B 79...
Страница 80: ...Notes...
Страница 81: ...Notes...
Страница 82: ...Notes...