Removing the
Rate-Control-Manifold Valve
1.
Remove the clamps and gaskets that secure the
manifold for the rate-control valve (
).
Note:
Retain the clamp(s) and gasket(s) for
installation in
Installing the Rate Control Manifold
.
g033304
Figure 62
1.
Flange (pressure-filter
head)
4.
Clamp
2.
Manifold (rate-control
valve)
5.
Gasket
3.
Flange (agitation valve)
6.
3-pin connector (valve
actuator—rate-control
valve)
2.
Remove the retainer that secures the outlet
fitting to the manifold for the rate-control valve
(
).
g033313
Figure 63
1.
Flanged-head bolt
4.
Retainer
2.
Valve mount
5.
Socket (outlet fitting)
3.
Flanged locknut
6.
Manifold-valve assembly
3.
Remove the 2 flanged-head bolts and 2 flanged
locknuts that secure the rate-control valve to
the valve mount and remove the valve manifold
from the machine (
).
Note:
If necessary, loosened the mounting
hardware for the pressure-filter head to ease
removal of the rate-control valve.
Removing the Agitation-Manifold
Valve
1.
Remove the clamps and gaskets that secure
the manifold for the agitation valve (
) to the agitation-bypass valve, rate-control
valve, master-section valve, and adapter fitting
(agitation-throttle valve).
Note:
Retain the clamp(s) and gasket(s) for
installation in
Installing the Agitation-Manifold
.
2.
Remove the retainer that secures the outlet
fitting to the manifold for the agitation valve
(
).