Relays (Fig. 19, 20)
To test a relay, disconnect the relay wire connector and
install a continuity tester between the relay terminals
(terminals 30 and 87). The relay should make and break
continuity at terminals 30 and 87 as 12 V.D.C. is con
nected and disconnected to terminal 85 with terminal 86
connected to ground.
Resistance specifications:
Terminals 85 and 86 = 80 to 90 Ohms
Terminals 30 and 87a (normally closed) = continuity
Terminals 30 and 87 (normally open) = continuity when 12V
DC is applied to terminals 85 and 86
Figure 19
Figure 20
Battery
Use a hydrometer to test the battery. Charge the battery
if necessary (see Battery Service).
Electrolyte Specific Gravity
Fully charged: 1.250 - 1.280
Discharged: less than 1.240
Testing
Page 5 - 22
Hydroject 3010
Содержание HydroJect 3010
Страница 2: ...Hydroject 3010...
Страница 4: ...Hydroject 3000 4000...
Страница 10: ...Equivalents and Conversions Product Records and Maintenance Page 2 2 Hydroject 3010...
Страница 44: ...Repairs Page 4 26 Hydroject 3010...
Страница 72: ...Repairs Page 5 28 Hydroject 3010...
Страница 102: ...This page is intentionally blank Repairs Page 6 28 HydroJect 3010...
Страница 109: ...IRXU ORFDWLRQV 7RUTXH WR IW OE LJXUH GURMHFW 3DJH 5HSDLUV...
Страница 118: ...This page is intentionally blank Electrical Diagrams Page 8 2 Hydroject 3010...
Страница 119: ...Page 8 3 Electrical Schematic Hydroject 3010...
Страница 120: ...Hydroject 3010 Main Harness Page 8 4...
Страница 121: ...Page 8 5 Main Wiring Diagram Hydroject 3010...
Страница 122: ...Hydroject 3010 Control Panel Harness Page 8 6...
Страница 123: ...Hydroject 3010 Tiller Wire Harness and Diagram Page 8 7...
Страница 124: ......