Groundsmaster 4000--D
Page 5 -- 28
Electrical System
Temperature Gauge
The temperature gauge can be tested using a new
gauge as a substitute or by the use of a DC voltage
source and a variable resistance box.
CAUTION
Make sure the voltage source is turned OFF be-
fore connecting variable resistance to the elec-
trical circuit to avoid electrical shock and to pre-
vent damaging the gauge.
1. Connect temperature gauge to the variable resis-
tance and DC voltage source (Fig. 44).
NOTE:
When reading the gauge test point, there are
two white dots on the gauge face below the edge of the
glass cover for the each test point. For each variable re-
sistance setting, the needle must be pointed between
the two white dots.
2. Take test point readings (Fig. 45).
IMPORTANT: Allow circuit to warm up for at least 5
minutes before taking test readings.
A. Set variable resistance to 71 ohms. Apply a 14 +
0.01 VDC to the circuit. The needle should point to
the middle of the green area (80
o
C).
B. Set variable resistance to 38 ohms. The needle
should point between the green and red area
(105
o
C).
3. Turn off the voltage source. Disconnect voltage
source, gauge and variable resistance.
Figure 44
+
--
VARIABLE
RESISTANCE
14 VDC + 0.01 VDC
1. Middle position
2. High temp position
3. Edge of glass cover
Figure 45
1
2
3
Содержание Groundsmaster 4000-D
Страница 2: ...Groundsmaster 4000 D This page is intentionally blank ...
Страница 4: ...Groundsmaster 4000 D This page is intentionally blank ...
Страница 10: ...Groundsmaster 4000 D Page 1 6 Safety This page is intentionally blank ...
Страница 12: ...0 09375 Groundsmaster 4000 D Page 2 2 Product Records and Maintenance Equivalents and Conversions ...
Страница 34: ...Groundsmaster 4000 D Page 3 18 Kubota Diesel Engine This page is intentionally blank ...
Страница 43: ...Groundsmaster 4000 D Hydraulic System Page 4 9 This page is intentionally blank Hydraulic System ...
Страница 55: ...Groundsmaster 4000 D Hydraulic System Page 4 21 This page is intentionally blank Hydraulic System ...
Страница 107: ...Groundsmaster 4000 D Hydraulic System Page 4 73 This page is intentionally blank Hydraulic System ...
Страница 111: ...Groundsmaster 4000 D Hydraulic System Page 4 77 This page is intentionally blank Hydraulic System ...
Страница 117: ...Groundsmaster 4000 D Hydraulic System Page 4 83 This page is intentionally blank Hydraulic System ...
Страница 131: ...Groundsmaster 4000 D Hydraulic System Page 4 97 This page is intentionally blank Hydraulic System ...
Страница 145: ...Groundsmaster 4000 D Hydraulic System Page 4 111 This page is intentionally blank Hydraulic System ...
Страница 155: ...Groundsmaster 4000 D Hydraulic System Page 4 121 This page is intentionally blank Hydraulic System ...
Страница 161: ...Groundsmaster 4000 D Hydraulic System Page 4 127 This page is intentionally blank Hydraulic System ...
Страница 212: ...Groundsmaster 4000 D Page 5 38 Electrical System This page is intentionally blank ...
Страница 253: ...Groundsmaster 4000 D Page 7 11 Chassis This page is intentionally blank Chassis ...
Страница 264: ...Groundsmaster 4000 D Page 7 22 Chassis This page is intentionally blank ...
Страница 269: ...Groundsmaster 4000 D Cutting Decks Page 8 5 This page is intentionally blank Cutting Decks ...
Страница 282: ...Groundsmaster 4000 D Foldout Drawings Page 9 2 This page is intentionally blank ...
Страница 292: ...Page 9 12 Groundsmaster 4000 D Engine Wire Harness STARTER STARTER STARTER ...
Страница 294: ...Page 9 14 Groundsmaster 4000 D Front Wire Harness FLOW DIVIDER SOLENOID ...