Paths –     1

2

3

4

Valve Box

Maximum communication wire  

length between the controller  

and the farthest decoder is  

13,600' (4,145m).

White Black

White Black

White Black

White Black

The maximum communication  wire length between the decoder  

module and the  solenoid is 410' (125m).
Recommended Cable for Decoder-to-Solenoid is the Paige

®

 P7351D,  

14 AWG, Solid Copper, 2-Conductor, Direct Burial cable.

To easily identify stations for troubleshooting,  

  install wires with the same color code as the station wires.

Output Board

   White Power/Communication Wire 

Black Power/Communication Wire

     Station 1

   Solid Red Station Wire - Connect to the Red/White solenoid wire 

Red with Black Stripe Station Wire - Connect to the Black solenoid wire

      Station 2

   Solid Green Station Wire - Connect to the Red/White solenoid wire 

Green with Black Stripe Station Wire - Connect to the Black solenoid wire

      Station 3

   Solid Orange Station Wire - Connect to the Red/White solenoid wire 

Orange with Black Stripe Station Wire - Connect to the Black solenoid wire

     Station 4

   Solid Blue Station Wire - Connect to the Red/White solenoid wire 

Blue with Black Stripe Station Wire - Connect to the Black solenoid wire

Each station can activate up 

to two DC Latching Solenoids.

Out to additional 

decoder modules

Station Wires

The GDC output board can 

accommodate up to 100 stations-

  . The decoder modules can be 

connected in any configuration 

using the four output paths.

1-Station 

Decoder 

Module

When possible, install the decoder module in 

a valve box for ease of service.

DC Latching 

Solenoid

Red

Black

Recommended Cable for Controller-to-Decoder  

is the Paige

®

 P7350D, 14 AWG, Solid Copper,  

Jacketed 2-Conductor, Direct Burial cable.

Figure 4

 

Содержание GDC 200

Страница 1: ...location that shades the controller during the hottest hours of the day and provides as much protection from direct sunlight rain wind and snow as possible DO NOT mount the controller where it is expo...

Страница 2: ...er wire near the top of the ground rod Avoiding wire bends of less than 8 20 3cm radius and more than 90 route the wire through conduit and into the cabinet Secure the wire to the copper ground lug Ma...

Страница 3: ...e power cables and secure them to the terminal block Reference Table 1 for the appropriate type of power connection Step 4 Reinstall the power supply cover Step 5 Apply power to the controller WARNING...

Страница 4: ...ll applicable local and national electrical codes Use only wire approved for direct burial if installing the wires underground without conduit All field wiring splices must be accessible to facilitate...

Страница 5: ...ation Wire Connect to the Red White solenoid wire Green with Black Stripe Station Wire Connect to the Black solenoid wire Station 3 Solid Orange Station Wire Connect to the Red White solenoid wire Ora...

Страница 6: ...m the decoder and controller to decoder cable Use 3M DBR Y to properly water proof all wire connections See Figure 5 Step 4 Connect the lightning arrester s ground wire to the ground rod or plate s wi...

Страница 7: ...ontrol a master valve or a pump relay if the system requires it Step 1 Place the controller s power switch to OFF Step 2 Connect the Positive Hot wire of the power source that controls the master valv...

Страница 8: ...the ribbon cable back to the timing mechanism socket Step 8 Place the controller s switch to ON Electromagnetic Compatibility Domestic This equipment has been tested and found to comply with the limit...

Отзывы: