background image

excessively or not run under a sufficient load. If
multiple successive regenerations are required,
it may indicate that the DPF will require service
soon, that an engine problem exists (e.g.,
incorrect engine fuel or oil) or that a DPF
pressure sensor is failing.

Important:

A stationary regeneration can

be initiated by the engine ECU or by you,
the user. You can monitor the DPF soot
percentage on the Engine-Off Screen or in
the Maintenance and Service Menu. If the
DPF Soot percentage is high, you may elect
to initiate a manual stationary regeneration
on the DPF Soot Percentage screen in the
Maintenance and Service Menu by selecting
Yes at the prompt.

g217322

Figure 9

1.

DPF soot percentage

3.

Previous

2.

Start Regen

4.

Next

Important:

During a stationary regeneration,

ensure that the machine is parked on a
hard, level surface in a well-ventilated area.
This process runs the machine at a higher
exhaust temperature for approximately 30
minutes to burn off collected particulate in
the DPF.

Note:

You cannot use the machine during a

stationary regeneration.

When the engine ECU determines that a
stationary regeneration is required, the module
displays the Allow Stationary Regen? prompt
screen. Select Y (yes) to start the stationary
regeneration process or N (no) to delay the
process.

Ensure that the machine has at least 1/4
tank of fuel. Disengage the blades, move the
motion-control levers to the N

EUTRAL

-L

OCK

position, and engage the parking brake.

g216640

Figure 10

1.

Allow Stationary Regen

3.

No

2.

Yes

If you select N (no), the module displays a
120-minute countdown bar graph screen.

g216641

Figure 11

1.

Stationary Regen Required

If you do not perform a stationary
regeneration before the timer expires, the
engine enters a limp mode and the engine
ECU will require a recovery regeneration to
be performed. When the module indicates
that the engine has entered limp mode, the
engine speed and/or power is reduced and it
prevents clutch engagement.

g216677

Figure 12

1.

Engine Limp Mode Active

If you select Y (yes), the module prompts you
to start the regeneration process (

Figure 13

).

7

 

Содержание 72144

Страница 1: ...ly Read your Operator s Manual for more information Screen Icons The information screen uses the following icons Gauge and Meters Low Engine Speed Processing Advanced Settings Transmission Oil Mainten...

Страница 2: ...Presence Control OPC Increase Next Max Engine Speed Play Start Reset Efficient Engine Speed Pause Stop Error Warning Hydraulic Fluid Temperature Engine Glow Plugs Active Engine Diesel Particulate Filt...

Страница 3: ...ow Speed Transmission High Speed Product Overview g362360 Figure 1 1 Deck lift and wing deck fold unfold switch 4 High Low speed range switch 2 Key switch 5 Horizon display monitor 3 Blade control swi...

Страница 4: ...Note During startup the alarm sounds briefly to verify functionality Information Screens The main information screens are as follows Startup Screen page 4 Engine Off Screen page 4 Engine On Screen pag...

Страница 5: ...level drops to approximately 3 8 L 1 US gallon remaining in the tank Recommended Engine Cooldown Time The recommended time to idle the engine before it shuts down is shown on a bar display The level...

Страница 6: ...regeneration process the exhaust temperatures rise and could ignite flammable materials Use caution if you operate the machine around flammable materials If an auto regeneration is needed but operati...

Страница 7: ...nutes to burn off collected particulate in the DPF Note You cannot use the machine during a stationary regeneration When the engine ECU determines that a stationary regeneration is required the module...

Страница 8: ...to engage the parking brake and move the motion control levers to the NEUTRAL LOCK position Figure 14 g216674 Figure 14 1 Set brake and neutral C Ensure that the blades are disengaged D Ensure that t...

Страница 9: ...t the process the module displays the Regen Interrupted screen Figure 18 If you initiated the process the module exits the process If the process was initiated by the engine ECU the ECU places the eng...

Страница 10: ...ers Menu page 14 Advanced Settings Menu page 16 g257032 Figure 21 1 Maintenance and Service 5 Cancel Exit 2 Language 6 Toggle between screens 3 Gauges and Meters 7 Enter Return 4 Advanced Settings Mai...

Страница 11: ...tly active Outputs with numerical values display the current value You can toggle through all the outputs by pushing the pushing the button g038556 Figure 23 1 Status of outputs 3 Clutch output 2 Spee...

Страница 12: ...gure 26 1 Hydraulic transmission oil 2 Service History display 3 Service reminder reset was performed e g 250 and 750 engine hours Engine Oil This service reminder screen displays the hours until the...

Страница 13: ...een displays the serial number and model number of the machine g030190 Figure 31 1 Machine Information 3 Serial number 2 Model number Module Information The screen displays the current installed versi...

Страница 14: ...eset 3 Y yes 2 Are you sure 4 N no PTO Hours This screen displays a non resettable total PTO hour counter and a resettable trip PTO counter g030204 Figure 37 1 PTO Hours 3 Trip hours 2 Total hours 4 R...

Страница 15: ...n is available Pressing the reset button resets all 3 parameters Pressing the play button starts data collection g038364 Figure 41 1 Trip Statistics 1 4 Displays US gallons liters of fuel 2 Displays e...

Страница 16: ...Fan Settings page 19 Calibrate Engine Settings page 20 Factory Defaults page 20 Engine Oil After performing the necessary maintenance this screen allows you to reset the number of hours until the engi...

Страница 17: ...g267031 Figure 47 1 Reset gear box oil maintenance hours 3 Y yes 2 Are you sure 4 N no Wheel Drive Gear Box Oil This reminder screen allows you to reset the number of hours until the wheel drive gear...

Страница 18: ...ates that the audible alarm is active Pressing enter modifies the status of the audible alarm to On or Off g038366 Figure 52 1 Alarms 4 Toggle 2 Clutch Overcurrent 5 Enter 3 Fuel Low You can deactivat...

Страница 19: ...abled Adjust the Fan Settings These screens are used to adjust how often the fan reverses Figure 56 g320727 Figure 56 1 Fan settings 2 Adjust fan settings To change the fan reversal time interval pres...

Страница 20: ...ing the system returns the engine speed settings and alarm settings back to the factory default settings g030238 Figure 62 1 Factory Defaults 2 Reset When the exit screen appears press the enter butto...

Страница 21: ...han 9 V Clutch Overcurrent The cutting clutch current is too high Clutch Reset Required The PTO switch must be turned off to activate the PTO Engine Error Codes The system displays engine error codes...

Страница 22: ...e Safe Transport Mode limits the engine speed locks out the PTO and disengages the clutch a Low Oil Pressure message will display Cycling the key switch to the OFF and then to the ON position clears t...

Страница 23: ...and engine charging system Contact an Authorized Service Dealer System Voltage Low Blink Red System voltage below 12 3 V Check the battery and engine charging system Contact an Authorized Service Deal...

Страница 24: ...connections at the LDU and MCU module Wing Deck Interlock Fault Blink Red Disallow the clutch engagement disengage the clutch Wing deck not fully deployed Deploy the wing deck then cycle the PTO switc...

Отзывы: