background image

DANGER

Normal usage of the bag causes it to wear and
deteriorate over time. A worn or deteriorated bag
allows small objects to be thrown through the bag,
possibly injuring you or bystanders.

Check the bag frequently. If it is worn or
deteriorated, replace it with a genuine Toro
vacuum bag.

Separating the Vacuum Tube

g227719

Removing Clogged Debris
from the Impeller

1.

Turn off and

unplug

the appliance from the power source

and wait for all moving parts to stop.

2.

Remove the vacuum tube then remove the debris from
impeller blades.

g227760

3.

Check the impeller for any signs of damage. If it is damaged,
contact your Authorized Service Dealer.

4.

Install the vacuum tube, or, if you want to switch to blower
mode, the bottom inlet cover. Refer to

Converting from

Blower to Vacuum (page 3)

or

Converting from Vacuum to

Blower (page 3)

for more information.

Service

Toro has designed this product to give you years of trouble free
use. Should it need service, bring the product to your Authorized
Service Dealer. Your Toro Dealer is specially trained to repair Toro
products and will ensure that your Toro stays “All” Toro.

Double-insulated
Appliances

In a double-insulated appliance, two systems of insulation
are provided instead of grounding. No grounding means is
provided on a double-insulated appliance, nor should a means for
grounding be added to the appliance. Servicing a double-insulated
appliance requires extreme care and knowledge of the system,
and should be done only by the qualified service personnel at
your Authorized Toro Service Dealer. Replacement parts for a
double-insulated appliance must be identical to the parts they
replace. A double-insulated appliance is marked with the words
“Double Insulation” or “Double Insulated.” The symbol (square
within a square)

may also be marked on the appliance.

Storage

Store the appliance and extension cord indoors, in a cool dry
location, out of reach of children and animals.

Troubleshooting

If your blower fails to run when you turn it on, check the following
before contacting your Authorized Service Dealer:

Ensure that the bottom inlet cover or vacuum tube is locked in
place.

Ensure that the power cord is secured in place at the back of
the appliance and that the plug is fully seated.

6

 

Содержание 51617

Страница 1: ...Form No 3378 476 Rev D Rake and Vac and Super Blower Vacuum 51617 51618 Rake and Vac et super souffleur aspirateur 51617 51618 www Toro com 3378 476 D...

Страница 2: ...erly Keep hair loose clothing fingers and all parts of the body away from openings and moving parts Be aware of the position of the blower and the air inlets during operation Loose clothing jewelry an...

Страница 3: ...Toro com so that Toro can notify you in the case of a safety or warranty product recall g224170 Figure 2 1 Blower tube 3 Upper vacuum tube 2 Bottom inlet cover 4 Lower vacuum tube Assembling the Blow...

Страница 4: ...un unless the vacuum tube is locked in place Note If the motor runs without the inlet cover in place do not use the appliance Return it to an Authorized Service Dealer g227757 3 Adjust the bag strap a...

Страница 5: ...rician to install the proper outlet Do not change the appliance or extension cord plug in any way Use only an extension cord recommended for outdoor use WARNING If you do not fully seat the extension...

Страница 6: ...bris as needed WARNING Using the appliance as a vacuum can throw debris possibly causing serious personal injury to you or bystanders Do not operate the vacuum without the bag installed or with the ba...

Страница 7: ...is specially trained to repair Toro products and will ensure that your Toro stays All Toro Double insulated Appliances In a double insulated appliance two systems of insulation are provided instead o...

Страница 8: ......

Страница 9: ...t N autorisez pas les enfants utiliser l appareil Respectez les instructions d utilisation de ce manuel Utilisez uniquement les accessoires recommand s par le fabricant Portez des v tements ad quats N...

Страница 10: ...visibles par l op rateur sont plac s pr s de tous les endroits potentiellement dangereux Remplacez tout autocollant endommag ou manquant decal125 0476 125 0476 Mise en service Enregistrez votre produ...

Страница 11: ...e d aspiration est verrouill en position Remarque Si le moteur fonctionne alors que le couvercle d entr e n est pas en place n utilisez pas l appareil Renvoyez le un d positaire r parateur agr g227757...

Страница 12: ...i d installer une prise murale ad quate Ne changez surtout pas la fiche ni l appareil Utilisez uniquement une rallonge pr vue pour l ext rieur ATTENTION Si la rallonge n est pas parfaitement branch e...

Страница 13: ...il est utilis comme souffleur l appareil est r serv l usage domestique Utilisez le souffleur l ext rieur pour d placer les d bris selon les besoins ATTENTION L appareil en marche peut projeter des d b...

Страница 14: ...tation et recherchez l origine du probl me Vidage du sac ramassage 1 Arr tez et d branchez l aspirateur de la prise d alimentation 2 Videz le sac g017099 Ne laissez pas de d bris dans le sac Pour nett...

Страница 15: ...par le personnel qualifi de votre d positaire r parateur Toro agr Les pi ces de rechange d un appareil double isolation doivent tre identiques aux pi ces d origine Les appareils double isolation porte...

Страница 16: ......

Отзывы: