6.
Engage the parking brake.
7.
Set the throttle to the low I
DLE
position.
Performing a Parked Regeneration
Note:
For instructions on unlocking protected menus,
refer to
Accessing Protected Menus (page 18)
.
1.
Access the protected menu and unlock the
protected settings submenu (
); refer to
Accessing Protected Menus (page 18)
.
g028523
Figure 37
2.
Navigate to the M
AIN
M
ENU
, press the center
button to scroll down to the S
ERVICE
M
ENU
, and
press the right button to select the S
ERVICE
option (
Note:
The InfoCenter should display the PIN
indicator in the upper right corner of the display.
g212371
Figure 38
3.
In the S
ERVICE
M
ENU
, press the middle button
until the DPF R
EGENERATION
options displays,
and press the right button to select the DPF
R
EGENERATION
option (
g212138
Figure 39
4.
When the “Initiate DPF Regen. Are you sure?”
message displays, press the center button
(
).
g212125
Figure 40
5.
If the coolant temperature is below 60°C (140°F)
the “Insure
is running and above 60C/140F”
message displays. (
).
Observe the temperature in the display, and run
the machine at full throttle until the temperature
reaches 60°C (140°F), then press the center
button.
Note:
If the coolant temperature is above 60°C
(140°F) this screen is skipped.