Adjusting the
Master-Boom-Bypass Valve
Note:
Adjusting the master-boom-bypass valve reduces or
increases the amount of flow sent to the agitation nozzles
in the tank when the master-boom switch is set to the O
FF
position.
1.
Fill the sprayer tank 1/2 full with clean water.
2.
Move the machine to an open level surface.
3.
Set the parking brake.
4.
Set the range selector to the N
EUTRAL
position.
5.
Set the pump switch to the O
N
position.
6.
Set the agitation switch to the O
N
position.
7.
Set the master-boom switch to the O
FF
position.
8.
Increase the engine speed to full throttle and set the
throttle lock to the O
N
position.
9.
Adjust the master-boom-bypass handle to control the
amount of agitation occurring in the tank (
).
10.
Reduce the throttle speed to idle.
11.
Set the agitation switch and pump switch to the O
FF
position.
12.
Shut off the machine.
Maintenance
Changing the Pressure Filter
Screen
Service Interval:
Every 400 hours—Change the pressure
filter screen.
Note:
Optional pressure filter screens are available through
your authorized Toro parts distributor.
1.
Move the machine to a level surface, shut off the
sprayer pump, shut off the engine, and remove the key
from the starter switch.
2.
Align a drain pan under the pressure filter (
).
Figure 110
1.
Filter head
4.
Filter element
2.
Bowl
5.
O-ring (drain cap)
3.
O-ring (bowl)
6.
Drain cap
3.
Rotate the drain cap counterclockwise and remove it
from the bowl of the pressure filter (
Note:
Allow the bowl to drain completely.
4.
Rotate the bowl counterclockwise and remove it from
its filter head (
5.
Remove the old pressure-filter element (
Note:
Discard the old filter.
6.
Check the O-ring for the drain cap (located at the
threaded fitting of the bowl) and the O-ring for the
bowl for damage and wear (
52