background image

2.

Select the S

ETTINGS

option from the display

menu and select the next screen icon

.

3.

Enter the PIN number (

Figure 15

and select the

E

NTER

icon

.

4.

Scroll down to I

NFO

C

ENTER

option and select the

next screen icon.

5.

For changing the language, scroll down to the
L

ANGUAGE

option, select the next screen icon,

scroll down to the desired InfoCenter language,
and select the change icon

.

6.

For changing the units, scroll down to the U

NITS

option and select the IMP or M

ETRIC

option with

the change icon

.

7.

Select the previous screen icon

.

Setting the Service-Due
Indicator

The InfoCenter indicates the time until the next regular
service interval.

Use the InfoCenter along with the operation-mode
selector to change the service interval after
maintenance.

1.

Rotate the operation-mode selector to the

S

position (

Figure 19

).

g250713

Figure 19

2.

Scroll down, select the S

ERVICE

option from the

display menu, and select the next screen icon

.

3.

Enter the PIN number (

Figure 15

and select the

R

ETURN

icon.

4.

Scroll down, select the S

CHEDULE

option from

the display menu, and select the next screen
icon.

5.

Scroll down to the service procedure performed
(i.e. oil filter or grease points) and select the
next screen icon.

6.

Select the hour interval and select the change
icon (

) to reset the hours for that procedure.

7.

Select the save icon

.

Audible Alarms

The machine alarm sounds when the operator is out
of the seat and one of the following situations occur:

The traction is engaged.

The shift lever is not in neutral.

The auxiliary hydraulic lever is not in neutral
position and the parking brake is off.

The PTO switch is on and the parking brake is off.

The machine alarm sounds when:

The InchMode is active and you press the
InchMode enable switch on the control box.

The hydraulic temperature is too high.

The machine is in the attachment mode and the
ground speed is below the minimum work speed.

The engine oil pressure is low.

The InfoCenter sounds a beep (usually not heard
when the machine is in operation) when a fault or an
advisory occurs. Refer to

Figure 3

for an example of

an advisory.

9

 

Содержание 07511AA

Страница 1: ...tion 4 Symbols Glossary 4 Navigating in the InfoCenter 6 Using the Operation Mode Selector 6 Accessing the Protected Menus 8 Setting the InfoCenter Units and Language 8 Setting the Service Due Indicator 9 Audible Alarms 9 Changing the InfoCenter Display Brightness Contrast 10 Setting Up Parameters 10 Product Overview Controls InfoCenter Startup Screen When you start the machine the startup screen ...

Страница 2: ... Universal advisory code use for reference to the advisory 2 Cause identifies the reason the machine took the action 5 Instructions to suppress the advisory 3 Remedy action to be taken by the operator to resolve the issue Status Display This display allows you to view the fuel level coolant temperature hydraulic fluid temperature battery voltage engine speed the 3 point maximum height for transpor...

Страница 3: ...um work position for the current active attachment 6 3 point hitch lowered g249940 Figure 6 1 Battery voltage 2 Engine speed g249941 Figure 7 1 Engine coolant temperature 2 Hydraulic fluid temperature g249942 Figure 8 Machine hours and Fuel gauge 1 Machine hours 2 Fuel gauge g249943 Figure 9 Alert Example 1 Machine hours 3 Fault code 5 characters long 2 Fuel level alert 4 Number of active faults 3...

Страница 4: ...ise control Select Change Attachment mode Delete Scroll up Scroll down InfoCenter Icon Description cont d Edit the attachment Hydraulic circuit 1 Hydraulic circuit 2 More options above More options below Maintenance Service menu Increase value Decrease value Next screen Previous screen Engine oil pressure PTO enabled PTO engaged Exhaust filter regeneration is inhibited Exhaust filter regeneration ...

Страница 5: ...equires service Save Hour meter Forward Auto high mode Auto low mode Reverse Neutral Glow plugs are active Move the screen curser left Move the screen curser right Hydraulic fluid temperature Differential lock InfoCenter Icon Description cont d Stop safely as soon as possible Fuel level Cancel Enter Symbols are often combined to form sentences An example is shown below The machine hours indicate t...

Страница 6: ...eing moved to the work site To access Attachment Mode turn the operation mode selector to the A position Figure 10 Note Changing attachments mounted to the Outcross may require the input of a pin number Note Driving the machine in Attachment Mode operates the same as driving in Low Automotive Mode when the PTO switch is in the OFF AND DISABLED position and the auxiliary hydraulic lever is in the N...

Страница 7: ...lector to the I position Figure 13 g250709 Figure 13 To aid in the connection of attachments locate and use the tethered remote to direct the machine forward or reverse and to lift and lower the 3 point hitch You can also engage the PTO Setup Mode Use Setup Mode to access machine settings service details and basic machine information You can also add or adjust the operational parameters of an atta...

Страница 8: ...Toro distributor 1 In the Setup mode press any button to access the pop up menu bar at the bottom of the screen Figure 15 g249814 Figure 15 1 PIN number screen 2 Press buttons as shown in Figure 16 to enter your PIN code g250129 Figure 16 3 When you complete entering the PIN select the enter icon Figure 17 g250130 Figure 17 Note Entering the PIN allows access to configure the machine until you tur...

Страница 9: ...he PIN number Figure 15 and select the RETURN icon 4 Scroll down select the SCHEDULE option from the display menu and select the next screen icon 5 Scroll down to the service procedure performed i e oil filter or grease points and select the next screen icon 6 Select the hour interval and select the change icon to reset the hours for that procedure 7 Select the save icon Audible Alarms The machine...

Страница 10: ...able or disable Using the Attachment Parameters This machine is unique in that each attachment is set up before use and stored in the machine computer The attachment parameters set the limits for each attachment used with this machine Note Ensure that the parking brake is engaged when the operator is out of the seat when using a stationary attachment The following are characteristics of parameters...

Страница 11: ...lude a 3 point fertilizer spreader in which you need to slow the PTO speed to reduce spreader throwing distance or to slow the machine to maintain safe machine operation You can set the minimum speed alarm to remind the operator to maintain speed as soon as it is safe to do so Note With the proper parameter settings you can set the maximum operating speed and set the warning buzzer for the minimum...

Страница 12: ... 8 mm 3 16 inch narrower than the parameter setting If the supervisor sets this range to 0 the operator cannot change the spacing in any direction Using the Status Display to Record the Three Point Positions Note Ensure that the PTO drive shafts do not bottom out and cause damaged to the machine or the attachment See the attachment manual for the proper setup for the drive line angles and drive li...

Страница 13: ...n increments of 1 If the PTO is off lowering the attachment below this position is possible You cannot engage the PTO below the minimum work position Setting this position prevents damaging the attachments that depend on the height off the ground An example is a debris blower Drop Speed This controls the 3 point lower rate It is adjustable from 10 to 100 in 10 increments This helps prevent damage ...

Страница 14: ...then Raise Time This is the amount of time in seconds the 3 point dwells before lifting the attachment to the turnaround position This allows the attachment to stop before raising above the maximum 3 point PTO height It is adjustable from 0 to 25 seconds in 0 1 increments This prevents damage to the PTO shaft the machine or the attachment Attachment Minimum Engine Speed This is the minimum engine ...

Страница 15: ...lus or minus icons and select the next screen icon 24 Set the PTO shaft speed by using the plus or minus icons and select the next screen icon 25 Set the lifted PTO shaft speed by using the plus or minus icons and select the next screen icon 26 Scroll down and select the STANDARD rate out of the following options and select the next screen icon A LOW B MEDIUM C STANDARD 27 Set the delay lower time...

Страница 16: ...select the next screen icon 17 Set the 3 point maximum work position and select the next screen icon 18 Set the 3 point minimum work position and select the next screen icon 19 Set the drop speed and select the next screen icon 20 Set the raise speed select the next screen icon 21 Set the PTO shaft speed and select the next screen icon 22 Set the PTO engagement speed to STANDARD from the following...

Отзывы: