Engine Maintenance
General Air Cleaner
Maintenance Practices
Service Interval:
Every 50 hours
Every 200 hours
•
Inspect air cleaner and hoses periodically to maintain
maximum engine protection and to ensure maximum
service life.
•
Check air cleaner body for damage which could
possibly cause an air leak. Replace a damaged air
cleaner body.
•
Clean the air cleaner filter every 50 hours and change
every 200 hours (more frequently in extreme dusty
or dirty conditions).
Servicing Air Cleaner
1. Pull latch outward and rotate air cleaner cover
counter–clockwise.
Figure 47
1.
Air cleaner cover
2.
Filter
2. Before removing the filter, use low pressure
air (40 psi, clean and dry) to help remove large
accumulations of debris packed between the outside
of the primary filter and the canister.
Important:
Avoid using high pressure air which
could force dirt through the filter into the intake
tract. This cleaning process prevents debris
from migrating into the intake when the primary
filter is removed.
3. Remove and replace the primary filter.
41