![Toro 02858 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/toro/02858/02858_installation-instructions-manual_1133599006.webp)
6.
Assemble the retainer of the dust cap onto the
quick-connect fitting (
).
Note:
You will install the cap over the fitting in
Installing the Dust Cap (page 13)
.
Preparing to Test the
Hydraulic Pressure
Model 31654
Installing the Quick-Connect
Fitting
Machines with the Optional Road Light Kit
1.
At the right side of the traction pump, remove
the 3-pin connector labeled
BRAKE PRESSURE
SENSOR
from the brake-pressure transducer
(
).
g344293
g344324
Figure 13
1.
Brake-pressure
transducer
2.
3-pin connector (labeled
BRAKE PRESSURE SENSOR
)
2.
Remove the brake-pressure transducer from
the adapter at T-fitting of traction pump port-B
(
).
g344291
Figure 14
1.
Adapter fitting
(T-fitting—traction pump
port-B)
2.
Brake-pressure
transducer
3.
Assemble the quick-connect fitting into the
adapter fitting (
g344321
Figure 15
1.
Adapter fitting
2.
Quick-connect fitting
4.
Torque the quick-connect fitting to 27 N∙m (20
ft-lb).
5.
Assemble the test equipment onto the
quick-connect fitting (
).
6