6. While running the first few meters check that
the squeegee adjustment guarantees a perfect
drying action and that the detergent solution
flow is appropriate. It has to be sufficient to
wet the floor uniformly avoiding the leakage
of detergent from the splash guards. Always
consider that the correct quantity of solution
detergent depends on the type of floor,
dirtiness and machine speed.
SPEED ADJUSTMENT, FORWARD AND
BACKWARD
When working it is necessary to lift the
squeegee to enable the backward drive.
Before running the machine select the
maximum speed level during work. Press
buttons (+) and (-) to see the speed level on the
display.
To move the machine select the direction using
the lever (1) placed on the dashboard.
Press the pedal (2) placed on the footboard to
enable the drive.
Use the knob (3) to adjust the speed during
work. The speed will change from the minimum
to the maximum previously set and visible on
the display.
In standard mode the detergent solution flow
adjustment is made through the lever (1) both
in MAN and AUTO mode.
DETERGENT SOLUTION FLOW ADJUSTMENT
AUTOMATIC MODE WORK
1. Automatic mode is helpful to ease the
operator work.
2. Check that the machine is set in automatic
mode, if not press button (1) and the display
will show the corresponding symbol.
3. Lower the squeegee using the lever (2.
4. Press the drive pedal (3) on the footboard.
Once the pedal is pressed the machine runs
forward, the brush base goes down and
simultaneously the solenoid valve opens itself
and brushes and suction motor start working.
To adjust the detergent flow see under
“DETERGENT SOLUTION FLOW
ADJUSTMENT”.
After releasing the pedal: the brush base goes
up, the brushes motors stop, the solenoid valve
closes itself ,and the suction motor shuts off.
If, during the work in automatic mode:
- the brush base, solenoid valve or suction
motor button is pressed, the machine switch to
manual mode;
- the squeegee lever is lifted, the suction motor
shuts off after a few seconds; when the lever is
lowered the suction motor turns back on.