Faults with Display
Battery con-
trol display
Overload
display
Fault
Remedy
–
flashes
rapidly
Brush drive ex-
cess temperature
Switch the program selection switch to
OFF and let the appliance cool down.
–
flashes
slowly
Wrong cable con-
nections will lead
to disruptions and
overload on the
brushes.
Switch program selection switch to OFF.
Then reselect the cleaning program. Call
customer service if fault persists.
–
lights
Electronic fault
rapidly flash-
es red
flashes
rapidly
Defective battery
slowly flash-
es red
flashes
slowly
Short circuit cus-
tomer
Set program switch to OFF. Wait for a
while. Select the cleaning program
again. If the fault recurs, call customer
service.
Faults without Display
Fault
Remedy
Appliance cannot be start-
ed
Check batteries, charge if necessary
Check battery pole fuse at the plus pole of the battery (75A);
if the fuse is defective, call customer service.
Insufficient water quantity
Check the fresh water level, refill tank if required
Check if the hoses are blocked, refill tank if required
Insufficient vacuum per-
formance
Clean the seals between dirt water reservoir and cover and
check for tightness, replace if required.
Clean the fluff filter
Clean the vacuum lips on the vacuum bar, replace if required
Check if the suction hose is blocked, clean if required
Check the suction hose for tightness, clean if required
Check that the cover on the dirt water discharge hose is closed
Check the setting of the vacuum bar.
Insufficient cleaning result
Check the brushes for wear, replace if required
Brushes do not turn
Check if foreign bodies are blocking the brushes, remove for-
eign bodies if required