51
Diagnostic display
W-800
Diagnostic display
Number
State
Diagnosis / Remedy
The operator starts up and
“0”goes out.
In normal operation, drive receives start signal via START input
or by drive unit.
Garage door has reached end
position OPEN.
Garage door has reached end
position CLOSE.
End position has not been
reached.
The display shows a “0” during
the next opening and closing
cycle and then goes out.
The operator is carrying out a learning cycle for the force limit.
Caution: During this travel cycle the operator does not monitor
the force. Make sure that no persons or objects are in the travel
path of the garage door.
The display continues to show
a “0”.
The force learning cycle has not been completed and must be
repeated.
The door’s end position may have too much pressure. Reset the
end positions.
The door does not open or
close.
Interruption at STOP A or activation of an external safety device
(such as a pass-door).
The door does not close.
Interruption at STOP B or activation of an external safety device
(such as a photoelectric sensor).
The door setting and learning
cycle did not complete correctly.
You must use menu stages 3 and 4 to complete the door
settings correctly and then complete the force-learning cycle.
There is a permanent impulse
signal at the start input.
Start signal is not detected or pulse duration (eg button jammed).
An error occurred in setting the
operator.
The travel path is too long.
Repeat setting procedure with menu stages 3 and 4.
Error in learning cycle.
Repeat position learning cycle with menu stages 3 and 4.
Reduce force when approaching the end-of travel positions.
The door does not open or
close.
An error occurred during the self-test. Disconnect the power
supply.
System error.
Call a specialist company and charge them with the repair work.
Motor standstill.
The motor does not rotate. Call a specialist company to repair
the motor.
Electronic brake activated. The
garage light remains on.
The operator is pulled from upper end position. Check the door
and the springs. Setting upper end lower.
The vacation lock is activated.
The door does not open.
The side switch for SafeControl/Signal 112 is active. A reset is
required.
Wicket door contact test failed.
Check the cables and clamping connections of the wicket door
contact.