background image

SMS-TORK Endüstriyel Otomasyon Ürünleri San. Tic. Ltd. Şti.

20

8. GENERAL CARE, REPAIR AND CLEANING

The device must be checked by the user before used. All cables must be checked for bre-
akage, crushing, cracking etc; whether device’s connections are applicable according to 
use manual; whether taking protection for leakage. Before cleaning the device, cut off the 
electricity. Use soft cleaning solution and dry cloth. Do not use abrasive materials.

8. PRODUCT SHIPMENT

During transportation be careful about electrical actuator’s not falling down and not being 
subjected hard knocks. Don’t put any weight damaging the product on electrical actuator 
boxes. Electrical actuators must be carried on their carton boxes. 

9. WARRANTY CONDITIONS

1)

 The period of warranty shall start from the date of delivery of the product to the 

customer and shall cover a period of 2 years.

2)

 Every and all parts of the product are under SMS Sanayi Malzemeleri Üretim ve Satışı 

A.Ş. warranty coverage. (against any defect that may occur during production, assembly 
and/or defective parts)

3)

 In the case that the product fails within warranty period, the time spent on the repair 

work is added to the warranty period. Repair time of the product is maximum 20 (twenty) 
working days. This time starts from the date on which the failure concerning the product 
is notified to the service station and to seller of the product, dealer, agency, representative, 
importer or producer. It is possible to make the consumer failure notification by telephone, 
fax, e-mail, registered mail or similar. However, in case of disagreement, the obligation of 
proof belongs to the consumer.

4)

 Product replacement or refund is mandatory depending on the choice of the consumer 

in case one of the conditions below:

a) If failure occurs in the product at least four times in one year or six times with the  
condition of being within the warranty period.

b) If the maximum time for its repair is exceeded.

c) In case a service station is not exist by a report issued by seller, dealer, agency, 
representative, importer or producer respectively that, repair of the failure is not possible, 
exchange process will be carried out free of charge.

d)The warranty period of the products changed during the warranty condition is limited 

Содержание TREAE Series

Страница 1: ...valve automation TREAE SERIES ELECTRICAL ACTUATOR USER MANUAL www smstork com NOVEMBER 2018 PLEASE READ THE INSTRUCTIONS BEFORE USE...

Страница 2: ...s 6 3 PRODUCT OPERATION 7 a Storage Conditions 7 b Operation Conditions 7 4 PRODUCT INSTALLATION 8 a Valve Mounting 8 b ManualWorking 11 c Adjusting Cam and Limit Switches 12 d TechnicalDimensions 13...

Страница 3: ...torque while turning TREAE series electric actuators are produced as On Off Controlled Electric Actuator Electrical actuators manufactured by SMS TORK do not use asbestos PCB mercury and other prohib...

Страница 4: ...0300 b Product Coding System There may not be all the variations at the product coding table For more details please contact us OPTIONS 00 NA 01 PIU With Potentiometer Unit 02 LCU Local Control Unit W...

Страница 5: ...t and Part Pictures Gear Motor Cams and Limit Switches Position Indicator Manual Control Lever Control Card Fig 1 TREAE Electrical Actuator Fig 3 Electrical Actuator Parts Fig 2 TREAE Electrical Actua...

Страница 6: ...ed By Sms tork Co Inc www smstork com Fig 4 Label Details d Labeling Details Electrical actuators general information must be written on their labels Fig 3 shows a sample label and the information it...

Страница 7: ...onditions b Operation Conditions Small light and compact design On Off control 60 Nm torque value High moment with low energy consumption Mechanically manual control Manual control by electronic card...

Страница 8: ...tallation line voltage and voltage written on the label must be checked if they are in the same range Before the installation product s suitability to the system must be checked Before the installatio...

Страница 9: ...www smstork com 9 Fig 6 Valve Mounting...

Страница 10: ...SMS TORK End striyel Otomasyon r nleri San Tic Ltd ti 10 Fig 7 Valve Mounting with Bracket...

Страница 11: ...d near to the body is pull down By this way motor s connection with gears is cut Switch under the body is opened and closed by no 15 switch For switch to automatic control mode manual control lever is...

Страница 12: ...it Switches Fig 8 Cams and Limit Switches SW4 OLS SW3 CLS SW2 EOLS SW1 ECVLS OPEN LIMIT SWITCHES OPEN CAMS CLOSE CAMS CLOSE LIMIT SWITCHES 2 When card is on energy press both direction buttons on the...

Страница 13: ...www smstork com 13 d Technical Dimensions Fig 10 TREAE Electrical Actuator ABC Measures 193 80 70 50 36 155 165 30 M 20 X1 5 14 M8 M6 M5...

Страница 14: ...nual mode if it light up with right LED Close 1 No energy on card 2 No First Control Signal Right Open 1 There is valve close control signal 2 It works on manual mode if it light up with left LED Clos...

Страница 15: ...www smstork com 15 e Wiring Schemes 100 240 VAC On Off Wiring Schemes...

Страница 16: ...SMS TORK End striyel Otomasyon r nleri San Tic Ltd ti 16 24 VDC VAC On Off Wiring Schemes...

Страница 17: ...and forcing the electrical actuator This forcing makes difficult to open or close the valve and can damage the electrical actuator When manual hand wheel has traced to its limits it must not be turne...

Страница 18: ...l actuator is clean Be sure about cable glands and blind plugs are mounted and dry Be sure about if there is no humidity in actuator Be sure about inner heater is working The internal heater prevents...

Страница 19: ...d insurance must be checked Manual on off handle turns hardly Valve shaft does not greased enough Valve shaft must be greased Actuator gear greased has problem Gears must be geared with proper one Val...

Страница 20: ...ly and or defective parts 3 In the case that the product fails within warranty period the time spent on the repair work is added to the warranty period Repair time of the product is maximum 20 twenty...

Страница 21: ...ose damages caused by natural disasters such as fire lightning flood earthquake etc 6 A report prepared by the SMS Sanayi Malzemeleri retim ve Sat A will determine whether the damage was caused by imp...

Страница 22: ...SMS TORK End striyel Otomasyon r nleri San Tic Ltd ti 22 SECTOR LEADER WITH 30 YEARS EXPERIENCE...

Страница 23: ......

Страница 24: ...nbul TURKEY P 90 216 364 34 05 F 90 216 364 37 57 FACTORY MES O S B S Cad No 5 erkesli Dilovas KOCAEL TURKEY P 90 262 290 20 20 F 90 262 290 20 21 SMS TORK End striyel Otomasyon r nleri San Tic Ltd ti...

Отзывы: