309.4 Operation.
Operable parts shall be operable with one hand and shall not require tight grasping,
pinching, or twisting of the wrist. The force required to activate operable parts shall be 5 pounds (22.2
N) maximum.
307 Protruding Objects
307.1 General. Protruding objects shall comply with 307.
307.2 Protrusion Limits.
Objects with leading edges more than 27 inches (685 mm) and not more than
80 inches (2030 mm) above the finish floor or ground shall protrude 4 inches (100 mm) maximum
horizontally into the
circulation path
.
EXCEPTION:
Handrails shall be permitted to protrude 4½ inches (115 mm) maximum.
Advisory 307.2 Protrusion Limits.
When a cane is used and the element is in the detectable range, it
gives a person sufficient time to detect the element with the cane before there is body contact.
Elements located on circulation paths, including operable elements, must comply with requirements for
protruding objects. For example, awnings and their supporting structures cannot reduce the minimum
required vertical clearance. Similarly, casement windows, when open, cannot encroach more than 4
inches (100 mm) into circulation paths above 27 inches (685 mm).
Figure 307.2 Limits of Protruding Objects Figure
5510202 and 5510282 meet ADA technical requirements for operation and pull force. They operate
with less than 5lbs force and with one hand.
Compliance with ADA mounting guidelines is the responsibility of the installer and building owner. Local
and state requirements may differ from ADAAG guidelines.