status until the next scheduled event. CH# will flash
when the load is overridden from scheduled event.
If the channel is a signal timer, then load will
turn on each time the override key is pressed
for the length of SIG1 duration. CH# will flash
while the load is on. While the signal is in
progress, it can be terminated by using over-
ride key.
NOTES:
1.
Unit will go to RUN MODE automatically if no key
is pressed for five minutes.
2.
Units do not have look back feature. If you have
just finished setting the unit and an output is to be
presently ON, press the OVR key to turn it 0n. Unit
will automatically pick up the regular schedule
thereafter.
3.
Units do not have stagger start.
4.
Clear all memory. All memory can be cleared
using the following procedure: while in the RUN
mode, press Enter key, display shows:
Use ON/OFF key to display:
Now press ENTER briefly and everything in the
timer memory is wiped off including real time and
date.