PUMP ASSEMBLY PARTS LIST 

 

Index #

 

Description

 

Part Number

 

Qty.

 

P1 

Base   

QF4-4 

P2 

Filter 

QF4-16 

P3 

Seal 

QF4-9 

P4 

Reservoir 

QF10-2 

P5 

Top Nut 

QF4-10 

P6 

Pump Foot 

QF4-11 

P7 

Nut M18 

GB6172-86 

P8 

O-Ring 7.7X1.9 

QLQ2.1-17 

P9 

Dipstick 

QF10.11 

P10 

Ball Φ5 

GB308-84 

P11 

Ball Φ8 

GB308-84 

P12 

Spring 

QF4-13 

P13 

Screw M10X1 

QF4-12 

P14 

Release Valve Stem 

QF4.2 

P15 

Seal 

QF4-14 

P16 

O-Ring 18X3.55G 

GB3452.1-92 

P17 

Seal 

QF4-41 

P18 

Clamping Nut 

QF4-17 

P19 

O-Ring 11.6x2.65 

QF4-42 

P20 

Seal 

QF4-18 

P21 

Piston 

QF4-2 

P22 

Socket 

QF4-5a 

P23 

Piston Pin 

QF4-3 

P24 

Pin Φ10 

QF4-1 

P25 

Snap Ring 10 

GB894.1-86 

P26 

Handle 

QF10-1 

P27 

Handle Grip 

QF4-7 

P28 

Hose 

QF4.3 

P29 

Coupling 

QF4.4 

P30 

Dust Cap 

QF4-15 

P31 

Ball Φ4 

GB308-84 

P32 

Spring Plunger 

QLQ2.1-16a 

P33 

Spring 

QLQ2.1-15 

P34 

O-Ring 5.8X2.8 

QLQ2.1-14 

P35 

Screw M10X1 

QF4-20 

P36 

Plastic Cap 

QF4-21 

Содержание BIG RED T71001L

Страница 1: ...rning to your retailer call our customer service department at 1 888 448 6746 8 a m 5 p m PST Monday Friday Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating Failu...

Страница 2: ...operate this product as intended may cause injury or death The manufacturer is not responsible for any damages or injury caused by improper use or neglect Allow product operation only with all parts...

Страница 3: ...NERAL SAFETY RULES WARNING Read and understand all instructions Failure to follow all instructions listed below may result in serious injury CAUTION Do not allow persons to operate or assemble this Pr...

Страница 4: ...e imminent structural failure stop using the product immediately and inspect it thoroughly Do not use to compress springs or any other item that could disengage and cause a potential flying hazard Use...

Страница 5: ...way Unauthorized modification may impair the function and or safety and could affect the life of the equipment There are specific applications for which the Ram Kit was designed Always check of damag...

Страница 6: ...y upon it immediately discontinue use until product has been clocked by a factory authorized service center contact distributor or manufacturer for list of Authorized Service Centers It is recommended...

Страница 7: ...Hydraulic Ram 2 Securely screw the Hose into the Hydraulic Ram 3 Insert the Pump Handle into the receptacle located at the top of the Pump Unit 4 To attach the Rubber Head the Extension Bars the Male...

Страница 8: ...Firmly close the Release Valve by turning it clockwise 2 Press the tip of the Hydraulic Hose Coupling against a hard surface and pump the pump handle 3 Continue pumping until the hydraulic fluid comin...

Страница 9: ...if bent broken or cracked components are noted OPERATION To Operate the Hydraulic Pump Unit 1 Position the Pump Unit on a stable flat and level surface 2 Close the release valve by turning it clockwis...

Страница 10: ...in which the damaged area needs to be pushed 5 Aim the pushing end towards the area that needs to be repaired and slowly apply pressure with the Pump Unit Once contact has been made on both points of...

Страница 11: ...pushed A hard secure surface will be required for to apply pressure on opposing sides A block of wood or a towel may be used to protect the sheet metal 5 Aim the pushing end towards the area that nee...

Страница 12: ...g against a non movable base Hold the Spreader Ram in position and apply the Pump Unit pressure Once contact on either end has been made step away as far as possible and continued to slowly apply pres...

Страница 13: ...cating inspect the equipment before use and lubricate when necessary After cleaning lubricate the equipment using light penetrating oil or lubricating spray Use a good lubricant on all moving parts Fo...

Страница 14: ...HER MATERIALS CLEAR WHEN POURING 4 Replace the Oil Fill Screw 5 Perform the Air Purge Procedure TO REPLACE OIL TO HYDRAULIC PUMP UNIT 1 Set Pump Unit flat on a level surface Remove the screw with its...

Страница 15: ...ILURE OF THE JACK AND THE POTENTIAL FOR SUDDEN AND IMMEDIATE LOSS OF LOAD DISPOSE OF HYDRAULIC FLUID IN ACCORDANCE WITH LOCAL REGULATIONS LUBRICATION 1 When not in use the Pump Unit should be stored w...

Страница 16: ...Poor performance CAUSES AND SOLUTIONS Releases valve not tightly closed Firmly close release valve Weight Capacity Exceeded Air is in the hydraulics Purge air from system Low oil level Add oil as requ...

Страница 17: ...10 QF10 10 10 1 4 Extension Tube 5 QF10 10 5 1 5 Pump Unit QF10 0 PUMP 1 6 Ram Assembly QF10 0 RAM 1 7 Spreader 1000lb Capacity QF4 7 1 8 Serrated Saddle QF10 7a 1 9 Combination Head QF10 6 1 10 Wedg...

Страница 18: ...18 PUMP ASSEMBLY...

Страница 19: ...Release Valve Stem QF4 2 1 P15 Seal QF4 14 1 P16 O Ring 18X3 55G GB3452 1 92 1 P17 Seal QF4 41 1 P18 Clamping Nut QF4 17 1 P19 O Ring 11 6x2 65 QF4 42 1 P20 Seal QF4 18 1 P21 Piston QF4 2 1 P22 Socke...

Страница 20: ...20 HYDRAULIC CYLINDER RAM ASSEMBLY...

Страница 21: ...ap TF1008G 11 1 11 Piston Cup T71003LT 7 1 12 O Ring 24 5X3 1 QF10 9 1 13 Ram T71003LT 6 1 14 Spacing Ring T71003LT 9 1 15 Ring Snap QF10 12 1 16 Protecting Cap QF10 11 1 17 Screw M6X20 GB70 85 1 18 C...

Страница 22: ...purchase for a period of one year from the date of that purchase the manufacturer will repair or replace at its discretion without charge any of its products or parts thereof which fail due to a defec...

Отзывы: