This  high-resolution  color  display  with  touch  screen  use  is 

specifically designed to meet the rigorous performance standards needed 
for diagnostic, interventional radiology, and other medical applications. 
To  guarantee  image  integrity,  features  include  accurate  signal 
conversion and a wide range of interfacing options. 

Compact design -Low weight and small size with improved performance make 
the color flat panel display HL1916S SERIAL  preferable to conventional 
CRT monitors.  
 
Embedded  LUT(Look  Up  Table  )-This  monitor  is  factory  calibrated  to 
achieve Gamma2.2 compliance and Linear gray level reproduction at the 
factory set point. Six different settings are stored within the display. 
 
Screen resolution- HL1916S SERIAL  is equipped with a panel with Twisted 
Nematic technology. The optimal picture resolution is 1280 x 1024 pixels. 
Video signals with other resolutions typical to medical engineering are 
optimally zoomed in or out to the screen size.  

Fast backlight stability- The luminance stabilization circuit employs 
a  built  in  photo  sensor  to  keep  the  back-light  lamps  at  a  constant 
luminance for consistent calibration over the life of the display and 
can control the back light system automatically to extend the life of 
the monitor 

Multi-interface for video inputs- Support DVI-D, VGA, DisplayPort. 

Embedded full functional stand base - The stand base is embedded inside 
the monitor and can be easily removed. The stand base is up/down and tilt 
adjustable. 

2. Declarations

 

 

Safety precautions  

 
 
 
 
 
 

WARNING

:  

To avoid risk of electric shock, this equipment must only be connected 
to a supply mains with protective earth. 

Medical Equipment 
With respect to electric shock, Fire and mechanical 
hazards  only    in    accordance    with  ANSI/AAMI 

ES60601-1:2005

CSA C22.2 No.60601-1:2008

 

Содержание HL1916SH

Страница 1: ...User Manual 19 inch Color LCD Display Model HL1916SH Rev A0...

Страница 2: ...13 6 Adjustments 14 6 1 Picture adjustment 14 6 2 Optimum picture quality 15 6 3 OSD menu 16 6 3 1 Keys assignment and operation LED 16 6 3 2 Key functions without active OSD menu 16 6 3 3Key functio...

Страница 3: ...hnology The optimal picture resolution is 1280 x 1024 pixels Video signals with other resolutions typical to medical engineering are optimally zoomed in or out to the screen size Fast backlight stabil...

Страница 4: ...e note that liquid crystal displays such as the HL1916S SERIAL do not have a failure rate of zero and image parameters may change over time e g luminance or discoloration Please ensure that all measur...

Страница 5: ...nnel When installing your medical electrical system with our products in an environment with patients please observe the safety requirements of EN 60601 1 IEC 60601 1 for Specifications for the safety...

Страница 6: ...icing this must not be carried out in the presence of patients the user or other persons not involved with servicing The following applies to installations in the USA and Canada Molded power supply pl...

Страница 7: ...ont panel is extremely sensitive to mechanical damage Avoid all scratches knocks etc Remove water drops immediately extended contact with water discolors the surface Clean the front panel when dirty u...

Страница 8: ...from a cold one water may condense upon it The unit should not be switched on until all the condensed water has evaporated including that inside the unit This may take several hours depending on the...

Страница 9: ...the display Caution Use a power cable with PE conductor corresponding to the safety requirements of the respective country of use Note for North America Molded power supply plugs must comply with the...

Страница 10: ...e 8 of 26 4 1 2 Cable attaching Connect the cables to the display VGA connector the flat panel display can be connected to the computer system using a VGA Cable on D sub connection for analog signal T...

Страница 11: ...can also be made via the DisplayPort connection The picture quality noise immunity and radiated interference of the complete system depend on the cable quality and length Serial connection you can co...

Страница 12: ...6 Note the stand base is optional 4 1 4 Mounting Use Remove the stand base according to the contrary way in 4 1 3 Fix the mount by mounting screws see page 6 table Mounting Screws for details Button o...

Страница 13: ...se the SMPTE test pattern Adjust the brightness so that image sections with 5 and 0 blackness still visibly contrast from one another Adjust the contrast so that image sections with 95 and 100 whitene...

Страница 14: ...ns All connectors should be of screw or locking types as far as possible Signal and power cables must not be routed in the same duct The display must not share a power supply with motors or valves gli...

Страница 15: ...socket to DIN 49 547 IEC 320 Caution A power cable with PE conductor must be used which corresponds to the safety requirements of the respective country of use 5 6 Serial interface Caution No other un...

Страница 16: ...out via the analog port The digital input DVI D DP does not require a fine adjustment since the display signal is always optimum RGB picture sources via VGA connector supply analog signals which are...

Страница 17: ...anged Control again the black value did not change In case it did you need to duplicate the two previous steps until it does not change anymore cause pedestal Increase the contrast level until the mea...

Страница 18: ...ion of the menus 6 3 OSD menu 6 3 1 Keys assignment and operation LED A dynamic help for keypad function is available for each menu it explains the role of each key depending on the OSD menu window wh...

Страница 19: ...SD menu Key s Situation Action Menu Always Jump to next line Up Slide controller Increase value Command Enter key Down Slide controller Decrease value Set Sub menu Return to previous menu 6 3 4 Menu c...

Страница 20: ...255 Shift picture in vertical direction Frequency Analog only 0 100 Adjust the frequency and phase of the input signal Hsync Phase Analog only 0 63 Source clock phase PhaseR Analog only R ADC clock ph...

Страница 21: ...horizontal position Vertical position 0 255 Adjustment of OSD vertical position Background 0 12 Select the OSD background transparency LED ON OFF Setting the status of the operation LED Language Engl...

Страница 22: ...Temp High on screen Temperature shutdown value has been reached Display will be automatically shut down after a certain time and turn on again when the temperature decreases enough again Other inform...

Страница 23: ...wer saving 5W Input Connector 3P IEC Type 8 3 Electronics Multi standard technology Video modes with resolutions less than 1280 x 1024 can be expanded to the TFT resolution and thus utilize the full d...

Страница 24: ...Composite Sync on Hs TTL LVTTL N or P VGA EDID datum EDID via VGA I C bus SOG Via VGA connector Analog R G B 0 7Vpp Input Impedance 75 Ohm Sync on Green 0 2 0 3V CVS Signal Via VGA connector monochro...

Страница 25: ...ature range 5 35 Temperature gradient Max 7 h no condensation Relative Humidity 15 85 Atmospheric pressure 70 106 kPa Transport and storage packed Item Set Width 416 5mm Depth 179mm Height 386 7 mm Ti...

Страница 26: ...8 2 27 single shock 150 m s 6 ms No permanent shock allowed in operating conditions Packed unit According to 2M2 EN60721 3 2 8 9 Safety specifications Safety standards EN60601 1 IEC60601 1 ANSI AAMI E...

Страница 27: ...in loss of the guarantee Information on the Instruction Manual For clarity reasons this Instruction Manual does not contain all detailed information on this product Your attention is additionally dra...

Страница 28: ...not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Cl...