7
Do not exceed the maximum applicable pressure of 300 kPa (43.5 PSI).
Higher pressures can damage the modules. Do not exceed the
maximum temperature of 40 degree C (104 degree F). The higher
temperature damages the modules.
Do not freeze the membrane modules.
The operating conditions, including the filtration flux and the periodical
physical cleaning, must be properly set-up otherwise the trans-
membrane pressure may rise too quickly. The operation range is
described in the latter section of this manual.
Make sure air tubes or pipings are properly fixed. Otherwise, the
tubes or pipings may blow away or behave violently during air
scrubbing.
Do not overfeed air to the modules. Excessive scrubbing air damages
the membranes and/or shortens the membrane life.
The air flow rate should be within the range below for each module type.
HFU-B2315AN: 3.6 – 6.7 Nm
3
/h (2.1 – 3.9 scfm)
The maximum required air pressure during the air-scrubbing for inside
of the module will be 40 kPa (6 PSI).
At the integrity tests, such as Pressure Decay Test (PDT) or Diffusive
Air Flow (DAF) Test, keep the air pressure below 130 kPa (18.9 PSI).
Keep the source air pressure lower than 200 kPa (29 PSI), to prevent
excess air inflow. All the air used for air scrubbing and integrity testing
must be dry oil-free air.
Prohibited
!
!
Instruction
!
!
Instruction
!
!
Instruction
!
!
Instruction
Prohibited