For Colibri PXA270:
Set the Jumper JP6 (next to the Ethernet connector) to 1-2.
For Colibri PXA3x0 and Colibri T20/T30:
Set the Jumper JP6 to 2-3.
See the Evalboard schematic for details about the jumper setting. (http://developer.toradex.com)
2.3 Migration Guide for Colibri Evaluation Board V2.1
For Colibri PXA270:
Set the Jumper JP7 (next to the Ethernet connector) to 1-2.
For Colibri PXA3x0 and Colibri T20/T30:
Set the Jumper JP7 to 2-3.
See the Evalboard schematic for details about the jumper setting.( http://developer.toradex.com)
The USB interfaces on the Evaluation board are not USB 2.0 high speed compatible. For more information see:
http://developer.toradex.com/knowledge-base/usb-2.0-high-speed-(480mbps)
Plug in the Colibri and power on the Evalboard. WinCE will start up.
All standard interfaces of the Colibri Evaluation board are now ready to use.
2.4 Evalboard Prior to Version 2.1
The Colibri modules will start up and all standard interfaces are available except Ethernet.
Ethernet is only supported for Colibri PXA270 modules.
Ask Toradex for more information about this. (
2.5 Orchid V1.0
For Colibri PXA270:
Set the Jumper JP2 (near the Ethernet connector) to 1-2.
For Colibri PXA3x0 and Colibri T20/T30:
Set the Jumper JP2 to 2-3.
The USB interfaces on the Evaluation board are not USB 2.0 high speed compatible. For more information see:
http://developer.toradex.com/knowledge-base/usb-2.0-high-speed-(480mbps)
Insert the Colibri module into the Orchid and power the device. The WinCE will start up and all interfaces will.