泰智科技
Shenzhen Topwisdom Technology Co., Ltd
2
accident and property loss.
Please do not piles up debris on the control box, and in the course of using,
regularly remove the dust of the control box surface and filters, to keep good
ventilation.
When users have to open the cover of the control box, must cut off the power after
5minutes and under the professionals
’ guidance, only can be allowed to touch the
components in the electrical control box!
Prohibit touching any motion parts or opening the control equipments when the
machine is working, or it may be bring about the accident and machine can
’t work.
Prohibit using the electrical equipment in the damp, dust, corrosive gas, flammable
gas area, or it may be cause the electrical shock or fire!
1.3 Work Environment
Ventilation, sanitation, and less dust
Storage temperature: 0-50
℃
Work temperature: 5-40
℃
Work relative humidity: 30%-90%(no condensation)
1.4 Power Supply and Grounding
1.4.1 Power Supply Requirements
Supply: DC 24V, 2A.
According to different machine configurations, power consumption is between
0.1-0.2KW.
1.4.2 Grounding Requirements
In order to prevent electrical equipment due to leakage, over-voltage, insulation etc
causes of the electrical shock or fire, please make the electrical control reliable
grounding.
Grounding resistance is less than 100 ohms; the length of wire cable is within the
20meters, the cross-sectional area of the wire cable is larger than 1.0 mm
2
.
Содержание TL-410
Страница 6: ...Shenzhen Topwisdom Technology Co Ltd IV...
Страница 10: ...Shenzhen Topwisdom Technology Co Ltd 4 connecting controller and PC 3 USB communication extended cable...
Страница 14: ...Shenzhen Topwisdom Technology Co Ltd 8 Fig 2 5...
Страница 35: ...Shenzhen Topwisdom Technology Co Ltd 29 Fig 3 21 Double click the System show as Fig 3 22 Fig 3 22...
Страница 36: ...Shenzhen Topwisdom Technology Co Ltd 30 Fig 3 23 Click the device management Fig 3 24 The assigned COM port...