Outdoor Dome Series | Quick Guide
15
A301DORZ / A501DORZ
A101DORV / A301DORV
2.2.5 Adjusting the camera position
The unit has three axes for adjusting field of view on different applications. While screening live view on your
monitor, adjust the position by procedures below simultaneously for desired focusing position.
Pan Adjustment (A)
Rotate the lens base (354° maximum) until satisfied with the field of view. Note that the side conduit hole
of bottom case is the point where the camera lens shouldn
’t be rotated over.
Horizontal Rotation (B)
Rotate 3D assembly in the lens base, but do not turn assembly more than 354° as this may have the
internal cables twisted, disconnected, or broken.
Tilt Adjustment (C)
After loosening the thumbnuts, tilt the camera lens to your desired angle, and then finger
–tighten the
thumbnuts to fix the position.
Figure 2 - 10: Adjusting the Camera Position
Caution
Limitation for three axes position:
Pan range : +164°
~
-190°
Rotate range : ±177°
Tilt range : 0°
~
80°
A
B
C
A
B
C