background image

- 24 -

user interface can also be used to switch a scanner to bypass, so that the topCam will not 
transfer the scanned codes to the PC.

Basic menu: “

Einstellungen von Datei laden

“ (Load from file), “

Einstellungen in Datei 

sichern

“ (Save in file) “

Trigger“

, ”

Z‚hler zurƒck setzen

“ (Reset counter)

Live image on/off, Bypass on/off
If the “Bypass” button is activated, the external trigger will be deactivated.

Содержание topCam 6500

Страница 1: ...1 Manual topCam 6500 Ver 3 5 4 topSenso GmbH Platanenring 10 D 61352 Bad Homburg Germany Contact Tel 49 6172 944606 Fax 49 6172 944607 E mail info topSenso de Internet www topSenso de...

Страница 2: ...ectrical connection 7 8 1 Power supply 7 8 2 In and outputs 7 8 3 Serial interfaces 8 8 4 TCP IP connector 8 9 Control monitor 9 10 Code sizes of the data matrix code 9 11 Print quality parameters and...

Страница 3: ...onal Various focal length and scanning windows Scanning distance 55 mm 80 mm 5 mm Lighting Internal LED flash red optionally white Optional external lighting 2 2 Inputs Outputs 2 potential free inputs...

Страница 4: ...interface 1 GND Reference potential for power supply 2 TXD Process interface 2 3 RXD Process interface 3 4 IN 2 unused 5 12 24 volts Power supply 6 assigned 7 RXD Service interface 3 8 assigned 9 TXD...

Страница 5: ...mm 36 x 27 mm 80 mm 56 x 42 mm 12 mm 55 mm 21 x 17 mm 80 mm 32 x 25 mm 100 mm 40 x 30 mm 120 mm 60 x 45 mm 9 5 mm 55 mm 24 x 18 mm 80 mm 34 x 25 mm 95 mm 40 x 30 mm 6 Symbologies Data matrix code ECC...

Страница 6: ...nal code interleaved 2 of 5 code 39 32 code 128 A B C EAN 8 13 UPC A E pharma code optionally with or without check sum length specifications 6 3 OCR OCV character set teachable max 40 characters mask...

Страница 7: ...supply voltage of 18 24 volts from pin 11 of the HD 15 connector The output signals are PNP signals Reference position for the inputs is pin 15 of the HD 15 connector The outputs are short circuit pro...

Страница 8: ...ns of the IP address The MAC address is associated with the serial number of the device which allows parallel connection of several topCams with different IP addresses on one switch The MAC address ca...

Страница 9: ...able vert horiz num alpha byte bytes 10 10 8 x 8 3 5 6 3 1 2 12 12 10 x 10 5 7 10 6 3 3 14 14 12 x 12 8 10 16 10 6 5 16 16 14 x 14 12 12 24 16 10 6 18 18 16 x 16 18 14 36 25 16 7 20 20 18 x 18 22 18 4...

Страница 10: ...ol user interface The topControl user interface allows operation of the topCam6500 via a PC COM port or to establish a communication via Ethernet for the topCam using an Ethernet adapter When the prog...

Страница 11: ...After the port has been selected the programme will start and establish the required connection with the topCam6500 Establishment of connection The setup parameters are loaded from the topCam6500 Then...

Страница 12: ...ize is used to specify the exact code size or if to be found automatically Orientierung Orientation defines the rotation in which the DM code is to be scanned 3 options fixed position rotated by 90 de...

Страница 13: ...Horizontales oder vertikales Scannen Horizontal or vertical scanning Omnidirektionales Scannen Omnidirctional scanning Auto discriminating or individual code types should be scanned When OCR OCV scan...

Страница 14: ...it will be scanned as one character The minimum distance between the characters should be at least 1 pixel The division factor is defined by the proportion height to width 10 The grey scale value thr...

Страница 15: ...aracters found are displayed in the user interface A function can be assigned to every character The following functions are available Lesen Scanning The character on the respective position will be s...

Страница 16: ...current character set of the camera is shown on the top After all characters have been assigned the settings are accepted by pressing the button bernehmen Accept In order to be able to scan the charac...

Страница 17: ...can be deleted Now an assignment can be made for the list in the table The number 1 has already been included in the character set and is contained in the top right corner in the character set An ass...

Страница 18: ...ly have a fixed position and assignment for verification This function is described in modus The character set can be up to 40 characters long Additional special settings can be set in the camera Howe...

Страница 19: ...e 2 trigger inputs is possible Example If 2 windows are active the different trigger inputs can be used to initiate a triggering In the centre of the picture below either trigger 1 or trigger 2 can be...

Страница 20: ...nitiated by sending the command STX TR CR Options By selection of the tab Optionen Options the following basic system settings can be realized Suspending the start up message Trace data matrix code af...

Страница 21: ...56 data matrix code post code Angle output of the code position Percentage of contrast Window number Print quality parameters Percentage of utilization of error correction bytes Start signal Separator...

Страница 22: ...ge a live image is displayed on the VGA monitor If the display screen is activated the current image will be permanently displayed ABE This function allows fine tuning of the lighting in order to achi...

Страница 23: ...y can be used for direct entry of commands which can be decoded by the topCam 6500 or selection of a new interface Komprimierte Daten bertragung Compressed data transmission Here the data transfer for...

Страница 24: ...not transfer the scanned codes to the PC Basic menu Einstellungen von Datei laden Load from file Einstellungen in Datei sichern Save in file Trigger Z hler zur ck setzen Reset counter Live image on of...

Страница 25: ...e after the adjusting window is aligned If scanning windows are selected the scanning window will be adjusted with the adjusting window and subsequently the line in the scanning window is scanned If o...

Страница 26: ...crimination is selected this item enables to find out which type of code was scanned Status identification in case of successful scanning 11 Code I2of5 start left 12 Code I2of5 start right 21 Code 39...

Страница 27: ...but 24 V are measurable at the blank trigger input instead This effect occurs when the supply of gate in and outputs has a wrong polarity The topCam6500 receives commands and also reacts to a trigger...

Страница 28: ...se as possible to the envelope so that the lighting is largely homogenous In the letter shop the small codes are printed at a module size of 17 mm In order to be able to scan the data matrix code in a...

Страница 29: ...9 Settings for the data matrix code The code scanner automatically orientates itself and seeks the number of grids In order to be able to scan a different data matrix code modifications are not requir...

Страница 30: ...t settings should be as follows The output format is preset as shown in the above settings The interface is adjusted to the individual requirements Some data transfers are defined by even parity In ot...

Страница 31: ...if the RS232 or the TCP IP port is to serve as process port Printing quality for data matrix code ECC200 For entering of limit values for which the scanning of the topCAm 6500 is considered as succes...

Страница 32: ...llows to save up to 8 complete settings under one name The saving and storing can also be realised with a short command via the interface When loading the parameters from the camera the products will...

Страница 33: ...t on the VGA monitor or in an image window of the topControl programme Use the button Fehlerbild auswerten Evaluate error image to evaluate the corresponding error image without recording a new image...

Страница 34: ...ata are stored in the log file A serial error can be set If the value is 0 the serial error is activated If the value for example is set to 5 this means that after 5 subsequent erroneous scans the err...