3.11
Fig.
41
1
2
3
A
26
K200T-K280T
EN
INSTRUCTIONS FOR INSTALLATION AND USE
Fasten the lateral caps on the beam using 3 screws type TSP d3.5x9.5 for each cap, supplied in the hardware package.
-
Drill symmetrical holes in the casing cover using a suitable drill with a Ø6.5 bit for aluminum, with the measurements
and position indicated in
Fig.41 Ref.4
Fasten the casing to the beam using two more screws type TSP d3.5x9.5 (
Fig.41 Ref.3
).
Apply an antivibration felt strip every 300mm along the beam (
Fig.41 Ref.1
).
Fit the upper part of the casing in its housing on top of the beam, holding it in a tilted position at a 30° angle and insert it until
it is flush (
Fig.41 Ref.2
).
If it should not be possible to fasten the casing from the side, proceed as follows:
-
Fasten the casing to the beam using the two screws type TCEI M5x10.
INSTALLING THE CASING
antivibration felt
M3,5x9,5 screws for
fastening casing
4
M5x10 screws for
fastening casing
Rating place and
“CE” marking
Содержание K200T