background image

This LED lights up when the input signal is too strong. In case of the
digital effect module being muted, this LED also lights up.

17- CLIP/MUTE LED

19

20

22

18

21

FOOT SW

FX SEND

FX RETURN

MAIN OUT

MONITOR

OUT

This jack is used to send out the signal from AUX bus.

19- FX SEND

This jack is used to return the sound of an effect unit to the main mix. You can also use it as an extra
auxiliary input.

20- FX RETURN

This jack is used to connect the input of an external monitor amplifier or active monitor speaker.

22- MONITOR OUTPUT

This jack is used to output the main mixsignal to an external unit.

21- MAIN OUTPUT

You can connect an external footswitch to turn the onboard effect
module on or off, via the 1/4" phone jack.

18- FOOTSWITCH

OUTPUT POWER: 2 100WATTS

MINIMUM SPEAKER LOAD: 2 OHMS

MADE IN P.R.C.

OUTPUT

AC INPUT

ON

OFF

POWER

SERIAL

MODEL

TAPE OUT

LEVEL

LEVEL

TAPE IN

FUSE

RATED POWER CONSUMPTION: 350W

110 127V

-

~ 60Hz T 3A

-

220 240V

-

~ 50Hz T 1.5A

-

-

8

+

10dB

VOLTAGE SELECTOR

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION:

REPLACE WITH THE SAME TYPE FUSE AND RATING
DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE

WARNING: SHOCK HAZARD

- DO NOT OPEN

AVIS: RISQUE DE CHOC ELECTRIQUE

- NE PAS OUVRIR

TPM4200FX MKII V2

115V

23

24

25

26

26

27

28

29

REAR PANEL

These connectors are used to output the signal to the speaker. The minimum speaker load is 2 ohms.

25- OUTPUT

23- LEVEL CONTROL
This control is used to adjust the level of TAPE IN. The adjustable range goes from -

to +10dB.

The unit features dual RCA jacks(left and right). If you wish to listen to your monitor from a tape
recorder, DAT or cassette, please use these TAPE IN jacks. Via the TAPE OUT jacks, you can route the
main output signal into a tape recorder or DAT for recording.

24- TAPE IN/TAPE OUT JACKS

Содержание TPM4200FX MKII V2

Страница 1: ...2 5KHz MID 12KHz MAIN 80Hz LOW 24 BIT EFFECTS PROCESSOR USB PLAYER OFF CH4 COMP LIM PHANTOM FOOT SW FX SEND FX RETURN MAIN OUT MONITOR OUT TPM4200FX MKII V2 1 2 3 1 2 3 1 2 3 1 2 3 88 ...

Страница 2: ...19 ...

Страница 3: ...N 4 2 FEATURES 4 3 USEFULL DATA 4 4 CONTROL ELEMENTS 5 5 INSTALLATION TIPS 12 6 CONNECTING DIAGRAM 12 7 WIRE CONNECTION 13 8 PRESET LIST 14 9 BLOCK DIAGRAM 15 10 TECHNICAL SPECIFICATIONS 16 11 GUARANTEE 17 12 NOTES 18 ...

Страница 4: ...res of TPM 4200FX MKII V2 Thanks again for choosing TOPP PRO 2 100W peak power amplifier Signal peak indication on channel 1 4 4line inputs through 1 4 jack 4 balanced MIC inputs through XLR jacks 2 band EQ on mono input channels 3 band equalizer on master output FX send for built in or external effects 24 bit DSP effects with 100 presets Monitor and effect sends on each channel Independent level ...

Страница 5: ...e gain range goes from 15dB to 15dB with a centre frequency of 10 kHz HIGH This is the bass control The gain range goes from 15dB to 15dB with a centre frequency of 100 Hz LOW 6 3 Band MASTER EQ Main Out This is the treble control You can use it to get rid of high frequency noises or to boost the sound of cymbals or high harmonics of human voice The gain range goes from 15dB to 15dB with centre fr...

Страница 6: ...efeatable and can be in the ON or OFF position depending upon your preference The LED will illuminate green when this switch is engaged 11 COMP LIM SWITCH This switch will apply 12 volt Phantom Power only to the XLR sockets When these XLR sockets are connected with devices that not require Phantom Power please make sure the Phantom Power is turned off failure to close may damage device 12 PHANTOM ...

Страница 7: ...LOAD 2 OHMS MADE IN P R C OUTPUT AC INPUT ON OFF POWER SERIAL MODEL TAPE OUT LEVEL LEVEL TAPE IN FUSE RATED POWER CONSUMPTION 350W 110 127V 60Hz T 3A 220 240V 50Hz T 1 5A 8 10dB VOLTAGE SELECTOR CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION REPLACE WITH THE SAME TYPE FUSE AND RATING DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE WARNING SHOCK HAZARD DO NOT OPEN AVIS RISQUE DE CHOC ELECTRIQUE NE ...

Страница 8: ... IEC receptacle connect your mixer to mains with the supplied power cord 28 AC INPUT 1 2 3 4 5 6 TAC MP3 S USB PLAYER Option One Song Module INSERT USB KEY Fig 1 MENU PROGRAM FOLDER LIST PLAYING Fig 2 These vents are used for ventilation and heat dissipation 26 VENTS This switch is used to turn on off the power of the unit 27 POWER SWITCH ...

Страница 9: ...wo Track Module The file system of USB memory for USB players is FAT16 and FAT32 and these players can only decode Mp3 It has 7 rank subordinate folders at most 5 6 7 1 8 3 4 2 USB PLAYER Push Hold POWER TAC MP3 T 2 PRE 3 NEXT 4 RPT Press this key the player will change between the following four modes REP ALL means to repeat all tracks in the memory mark on the screen is 2 5KHz MID 12KHz MAIN 80H...

Страница 10: ...Recording Module The file system of USB memory for USB players is FAT16 and FAT32 and these players can only decode MP3 It has 7 rank subordinate folders at most 5 6 7 1 8 3 4 2 9 USB PLAYER RECORDER USB PLAYER RECORDER TAC MP3 R VOL VOL RPT REC Push Hold POWER At normal state there is no selective mode on the front panel only a piece of panel without function Please connect the 5PIN row wire on t...