23
Operation
Manual pump operation
1. To flush the toilet, close the
seat and lid and give 8-10
steady pulls using the full
movement of the handle.
Pause for five seconds and
then continue pumping as
before for a further 5-6 strokes.
The higher the base of the
bowl is above the waterline,
the more strokes are needed.
(Also see note 8, page 16).
2. It is essential that a sufficient
number of strokes are used to
clear the system completely.
Use the full movement of the
pump handle. Avoid using
short jerky strokes. The num-
ber of strokes required will
vary according to the length of
the hoses.
NOTE: TO LEAVE TOILET
BOWL EMPTY OF WATER,
LIFT SEAT (13) AND THEN
OPERATE PUMP.
Electric pump operation
1. To flush the toilet, close the seat
and lid and press the push but-
ton fully in and release it.
2. The Lavac electric pump,
whether incorporated in the
Lavac electric toilet or used inde-
pendently as a pump for fluids,
should never be operated
against a seacock or any other
type of valve that is closed or
partially closed as this may
cause costly damage to the
pump. (Note: similar circum-
stances can arise if the hose is
blocked – see section on Check
points.)
3. Where a two-way valve or divert-
er valve is used in the system,
the pump should be switched off
whilst the direction of flow is
being changed as the valve has
a midway closed position.
4. Similarly where two or more
two-way diverter valves are in
the system, ensure that both
valves are set for a free dis-
charge before starting the elec-
tric pump.
HAND
VERSION
ELECTRIC
VERSION
1
2