The TDODS5-120 is a motion sensor with a dimmer. This innovative design makes it the single

most energy efficient controller ever! It’s capable of dimming at very low levels and it can deliver the 

brightest light that your bulbs are capable of handling. When the room is unoccupied, the sensor will 

automatically turn the lights off. The TDODS5-120 can be switched between Vacancy and Occupancy

modes and the sensor can be customized by adjusting the controls hidden under the dimmer buttons. 

NEUTRAL WIRE IS NOT REQUIRED FOR TDODS5-120

.

Model: TDODS5-120

Occupancy/Vacancy

Sensor & Dimmer

Voltage........................................................................................................................... 120VAC, 60Hz
Tungsten/ Incandescent................................................................................................................600W
Electronic self-ballasted (LED)..........................................................................................150W(1.25A)
Operating temperature.....................................................................................32°F~104°F(0°C~40°C)
Wire Strip Length.............................................................................................................16mm(5/8 in.)
Supply Connection .........................................................................................................#14-#12 AWG
Screw Torque.............................................................................................................................20lbf-in
Motion Sensor Coverage...............................................................................................180°, 700 sq.ft.

INSTALLATION INSTRUCTIONS

WARRANTY

© 2018 Top Greener, Inc. CA, U.S.A. WWW.TOPGREENER.COM  0206200101-4

WARNING

Read and understand these instructions before installing. This device is intended for installation in accordance 

with the National Electric Code and local regulations. It is recommended that a qualified electrician performs this 

installation. Make sure to turn off the circuit breaker or fuse(s) and make sure power is off before wiring the 

device.

Use copper wire only.

Turn the power off at the circuit breaker before installing the 

dimmer.

COVERAGE

As Illustrated below, the TDODS5-120 has a 180

° detection range with a maximum distance of 30’ 

detection in front of the sensor and 12’ on the sides, For Maximum results, the sensor must be properly 

installed between the height of 4’ to 5’ and away from obstructions such as walls, furniture and 

transparent barriers like Low-E glass.

Max. 12’

on the sides

Max. 30’

in the front

This device is warranted to be free of material and workmanship defects for 1 year from the date of purchase. Original receipt or proof of purchase from an authorized retailer must be presented upon warranty claim. ALL claims must be verified and approved by Top Greener, Inc. 

Warranties from other TOPGREENER products may vary. This warranty is nontransferable and does not cover normal wear and tear or any malfunction, failure, or defect resulting from misuse, abuse, neglect, alteration, modification, or improper installation. To the fullest extent 

permitted by the applicable state law, Top Greener, Inc. shall not be liable to the purchaser or end user customer of TOPGREENER products for direct, indirect, incidental, or consequential damages even if Top Greener, Inc. has been advised of the possibility of such damages. 

Top Greener, Inc’s total liability under this or any other warranty, express or implied, is limited to repair, replacement or refund. Repair, replacement or refund are the sole and exclusive remedies for breach of warranty or any other legal theory.

SPECIFICATIONS

FEATURES

WIRING DIRECTIONS: 

1. Remove the wall plate.

2. Remove existing switch from wall box and prior to disconnecting wires, identify the wires

    and label as needed.

3. Remove wires from existing switch.

4. Follow the diagram below to reconnect the TDODS5-120 sensor switch.

WARNING: The white wire you see in the wall box is not always the 

 

 

 neutral wire. Verify whether the power enters the wall or

 

 

 ceiling box first. 

NEUTRAL WIRE IS

 

 

 NOT REQUIRED FOR TDODS5-120

Load (Red)

Single-Pole

Wire the TDODS5-120 this way

if POWER enters the ceiling box first

Hot

Power

Neutral

Ground

Ceiling box

Wall box

Load

Hot (Black)

Ground (Green)

Remote (Blue) For 3-way & 4-way connections

Black

White with

non-neutral

marker

Single-Pole

If 

power enters 

the wall box first,

then wire the TDODS5-120 this way

Neutral

Ground

Ceiling box

Wall box

Load

Neutral (White)

POWER

Ground

Remote (Blue) For 3-way & 4-way connections

Load (Red)

Black

Black

Hot (Black)

5

Neutral

Ground

Ceiling box

Wall box

Load

Neutral (White)

Remote (Blue)

POWER

Load (Red)

Hot (Black)

Ground (Green)

Black

Ground (Green)

Neutral (White)

Travel (Red)

Travel (Red)

Travel (Black)

Load (Black)

Red

Remote (Blue)

Travel (Black)

3-Way Wiring

TDODS5-120

TDS3K

For 3-Way connections, you will need one TDODS5-120 and one TDS3K.

3-WAY AND 4-WAY WIRING

TDODS5-120

TDS3K

For 4-Way connections, you will need one TDODS5-120 and two or more TDS3K.

TDODS5-120

TDS3K 

x1

x2

x1

x1