The TDODS5-120 is a motion sensor with a dimmer. This innovative design makes it the single
most energy efficient controller ever! It’s capable of dimming at very low levels and it can deliver the
brightest light that your bulbs are capable of handling. When the room is unoccupied, the sensor will
automatically turn the lights off. The TDODS5-120 can be switched between Vacancy and Occupancy
modes and the sensor can be customized by adjusting the controls hidden under the dimmer buttons.
NEUTRAL WIRE IS NOT REQUIRED FOR TDODS5-120
.
Model: TDODS5-120
Occupancy/Vacancy
Sensor & Dimmer
Voltage........................................................................................................................... 120VAC, 60Hz
Tungsten/ Incandescent................................................................................................................600W
Electronic self-ballasted (LED)..........................................................................................150W(1.25A)
Operating temperature.....................................................................................32°F~104°F(0°C~40°C)
Wire Strip Length.............................................................................................................16mm(5/8 in.)
Supply Connection .........................................................................................................#14-#12 AWG
Screw Torque.............................................................................................................................20lbf-in
Motion Sensor Coverage...............................................................................................180°, 700 sq.ft.
INSTALLATION INSTRUCTIONS
WARRANTY
© 2018 Top Greener, Inc. CA, U.S.A. WWW.TOPGREENER.COM 0206200101-4
WARNING
Read and understand these instructions before installing. This device is intended for installation in accordance
with the National Electric Code and local regulations. It is recommended that a qualified electrician performs this
installation. Make sure to turn off the circuit breaker or fuse(s) and make sure power is off before wiring the
device.
Use copper wire only.
Turn the power off at the circuit breaker before installing the
dimmer.
COVERAGE
As Illustrated below, the TDODS5-120 has a 180
° detection range with a maximum distance of 30’
detection in front of the sensor and 12’ on the sides, For Maximum results, the sensor must be properly
installed between the height of 4’ to 5’ and away from obstructions such as walls, furniture and
transparent barriers like Low-E glass.
Max. 12’
on the sides
Max. 30’
in the front
This device is warranted to be free of material and workmanship defects for 1 year from the date of purchase. Original receipt or proof of purchase from an authorized retailer must be presented upon warranty claim. ALL claims must be verified and approved by Top Greener, Inc.
Warranties from other TOPGREENER products may vary. This warranty is nontransferable and does not cover normal wear and tear or any malfunction, failure, or defect resulting from misuse, abuse, neglect, alteration, modification, or improper installation. To the fullest extent
permitted by the applicable state law, Top Greener, Inc. shall not be liable to the purchaser or end user customer of TOPGREENER products for direct, indirect, incidental, or consequential damages even if Top Greener, Inc. has been advised of the possibility of such damages.
Top Greener, Inc’s total liability under this or any other warranty, express or implied, is limited to repair, replacement or refund. Repair, replacement or refund are the sole and exclusive remedies for breach of warranty or any other legal theory.
SPECIFICATIONS
FEATURES
WIRING DIRECTIONS:
1. Remove the wall plate.
2. Remove existing switch from wall box and prior to disconnecting wires, identify the wires
and label as needed.
3. Remove wires from existing switch.
4. Follow the diagram below to reconnect the TDODS5-120 sensor switch.
WARNING: The white wire you see in the wall box is not always the
neutral wire. Verify whether the power enters the wall or
ceiling box first.
NEUTRAL WIRE IS
NOT REQUIRED FOR TDODS5-120
Load (Red)
Single-Pole
Wire the TDODS5-120 this way
if POWER enters the ceiling box first
Hot
Power
Neutral
Ground
Ceiling box
Wall box
Load
Hot (Black)
Ground (Green)
Remote (Blue) For 3-way & 4-way connections
Black
White with
non-neutral
marker
Single-Pole
If
power enters
the wall box first,
then wire the TDODS5-120 this way
Neutral
Ground
Ceiling box
Wall box
Load
Neutral (White)
POWER
Ground
Remote (Blue) For 3-way & 4-way connections
Load (Red)
Black
Black
Hot (Black)
5
Neutral
Ground
Ceiling box
Wall box
Load
Neutral (White)
Remote (Blue)
POWER
Load (Red)
Hot (Black)
Ground (Green)
Black
Ground (Green)
Neutral (White)
Travel (Red)
Travel (Red)
Travel (Black)
Load (Black)
Red
Remote (Blue)
Travel (Black)
3-Way Wiring
TDODS5-120
TDS3K
For 3-Way connections, you will need one TDODS5-120 and one TDS3K.
3-WAY AND 4-WAY WIRING
TDODS5-120
TDS3K
For 4-Way connections, you will need one TDODS5-120 and two or more TDS3K.
TDODS5-120
TDS3K
x1
x2
x1
x1