4.5 Setting the Automatic Closing Time 

 

Important Note: When the auto close function is enabled, the photocell sensor is highly recommended to be 

installed with the gate opener for safety.   

 

4.6 Set the Safety Photocell Beam (SPB) System (Optional) 

 

1. Press and hold SET button for more than 4 seconds. 
The Digital Display indicates “1” (Skip  if continuing 
Closing Time Set after the Close Force Set is finished). 
2. Press UP button and choose figure “5” (Pic.4.5-1). 
Press and release SET button. “5” flashes in the Digital 
Display (Pic.4.5-2). Now the unit enters into Setting the 
Automatic Closing Time. 
3. Press  and release UP button. “

0

”  –“9” flashes in the 

Digital Display (default value is “

0

”, Automatic Closing 

function is closed) indicating current automatic closing 
time (Pic.4.5-3). The minimum time is 1 minute, 9 
minutes maximum. Each time press and release  UP 
button, the figure is bigger by 1, and the timing increases 
by 1 minute accordingly. Each time press and release 
DOWN button, the figure is smaller by 1, and the timing 
decreases by 1 minute accordingly (Pic. 4.5-4). When 
the  indication is “

0

”,  it means the Automatic Closing 

function is closed. 
4. Press SET button to store the data when desired 
Automatic Closing Time is set. “5” glows steadily in the 
Digital Display (Pic.4.5-5). The unit is ready for setting 
other parameter. Press SET button  for  seconds till “h” 
appears in Digital Display (Pic.4.5-6). Now the Automatic 
Closing Time has been set. 

1. Press and hold SET button for more than 4 seconds. 
The Digital Display indicates “1” (Skip if continuing SPB 
Set after the Closing Time Set is finished). 
2. Press UP button and choose figure “6” (Pic.4.6-1). 
Press and release SET button. “6” flashes in the Digital 
Display (Pic.4.6-2). Now the unit enters into Setting the 
Safety Photocell Beam (SPB) Function. 
3. Press and release UP button. The Digital Display 
indicates “1” (SPB is available).(Pig.4.6-3) Press and 
release DOWN button. The Digital Display indicates “

0

” 

(SPB is null) (Pig.4.6-4). 
4. Press SET button to store the data when SPB is set. 
“6” glows steadily in the Digital Display. (Pig.4.6-5).The 
unit is ready for setting other parameter. Press SET 
button  for seconds till “H”  or  “h”  appears in  Digital 
Display  (Pig.4.6-6). Now Setting the SPB Function is 
finished. 
NOTE: The unit doesn’t work until the SPB is equipped 
and “1” is set in the LED. 

 

Содержание MultiRuta CASAR 800

Страница 1: ...NER User s Manual Model CASAR 800 www topens com Email support topens com Please read and follow all warnings precautions and instructions before installation and use Save this manual C030554 VER 21a...

Страница 2: ...our automatic gate opener Where did you purchase Amazon com Amazon ca Amazon co uk Amazon de Other Please Specify Order Product Model Purchase Date Full Name Phone Email Address VERY IMPORTANT Street...

Страница 3: ...Door Bracket 13 3 7Assemble Door Arm NOT Bow Arm 14 3 8 Install Door Control Optional 15 3 9 Install the Safety Photocell Beam SPB System Optional 16 4 ADJUSTMENT SECTION 17 4 1 Learning the code 17 4...

Страница 4: ...bstruction during gate opening Reverse in case of obstruction during gate closing Soft start and soft stop each soft period can Not be adjusted Optional Accessories Parts List Available at TOPENS Stor...

Страница 5: ...2 Replacement Parts CKMJ2A Control Board WARNING Changes or modifications not expressly specified by this user manual TOPENS could void the warranty of this equipment...

Страница 6: ...eck that the opener reverses when the door contacts a 100mm 4 high object placed on the floor for opener incorporating an entrapment protection system depending on contact with the bottom edge of the...

Страница 7: ...ge door is in the colsed position and before you set the control board Do you have a finished ceiling in your garage If so a support bracket and additional fastening hardware not supplied may be requi...

Страница 8: ...on is as follows Terminal 1 for DOOR CONTROL BUTTON Terminal 2 for DOOR CONTROL BUTTON Terminal 3 for SAFETY PHOTOCELL BEAM SPB Terminal 4 for SAFETY PHOTOCELL BEAM SPB Terminal 5 for positive of Addi...

Страница 9: ...er back to this illustration of a completed installation NO Name NO Name 1 Header Sleeve 10 Manual Release Rope Handle 2 Idler Pulley Bracket 11 Curved Door Arm 3 Trolley 12 Straight Door Arm 4 Rail 1...

Страница 10: ...1 into the rail section which is with holes 2 2 Assemble the Driving Assembly The driving assembly consisting of driving wheel 2 wheel base 3 and splined sleeve 4 has been well assembled in the facto...

Страница 11: ...with holes 5 is in the farthest end from the opener 2 4 Fasten Rail to Opener and Install Chain Insert four bolts 1 into the holes of brackets 4 secure with elastic washer 2 and washer 3 Place rail 5...

Страница 12: ...l Header Sleeve and Tighten Chain Slide header sleeve 1 onto rail Slide flat washer 3 spring 2 and washer 3 onto carriage bolt 4 Thread nut 5 onto carriage bolt until finger tight Use an open end wren...

Страница 13: ...Position the Header Bracket The header bracket must be rigidly fastened to a structural support of the garage Reinforce the wall or ceiling with a 40 mm 1 1 2 board if necessary Failure to comply may...

Страница 14: ...ard the ceiling Mark all of the header bracket holes 5 Drill 4 5 mm 3 16 pilot holes and fasten the header bracket with wood screws 3 B Ceiling Mount Extend vertical center line 2 onto the ceiling Cen...

Страница 15: ...rary support The opener must either be secured to a support or held firmly in place by another person Raise the opener onto a stepladder Open garage door Place a 25mm 1 board 1 laid flat on the top se...

Страница 16: ...ckets with Nut 5 For concrete ceilings drill 8mm 0 3 pilot holes into ceiling and insert Concrete Anchors 2 Secure Hanging Brackets to ceiling with Lag Screws 3 For wood ceilings drill 4mm 0 16 pilot...

Страница 17: ...using hardware 3 4 and 5 With the door closed connect the straight door arm section 1 to the door bracket with clevis pin 6 Secure with R pin 7 Disconnect the inner and outer trolley Slide the outer...

Страница 18: ...e door control as a reminder of safe operating procedures Fasten the door control to an inside garage wall with sheet metal screws not provided A convenient place is beside the service door and out of...

Страница 19: ...photocell s receiver should be connected to the terminals 5 and 6 in parallel Use another 2 core cable to connect the NC terminal of the receiver to the terminal 3 the COM terminal to the terminal 4 N...

Страница 20: ...Codes Press and hold LEARN button on the Opener the Digital Display indicates before it comes to H The codes are now erased when the Digital Display flashes with H Pic 4 1 4 How to use the remote to c...

Страница 21: ...dily in the Digital Display Pic 4 2 4 Now setting the OPEN limit is finished 3 Press UP button and choose figure 2 Pic 4 2 5 Press and release SET button The Digital Display indicates 2 with flash Pic...

Страница 22: ...Press SET button for seconds till H appears in Digital Display Pic 4 3 6 Now the Open Force Adjustment is finished 1 Press and hold SET button for more than 4 seconds The Digital Display indicates 1 S...

Страница 23: ...4 5 4 When the indication is 0 it means the Automatic Closing function is closed 4 Press SET button to store the data when desired Automatic Closing Time is set 5 glows steadily in the Digital Display...

Страница 24: ...8 Wireless Keypad Programming Optional You can follow the below steps to program wireless keypad to the opener 1 Connect the Cord Plug to power supply The Digital Display flashes with H and the Light...

Страница 25: ...eview installation instruction warnings Is there a build up of ice or snow under door The door may be frozen to ground Remove any obstruction The garage door spring may be broken Have it replaced Open...

Страница 26: ...ns and closes by itself Make sure remote push button is not stuck on Door stops but doesn t close completely Repeat Setting the Limits see adjustment step 4 2 Repeat safety reverse test after any adju...

Страница 27: ...of operation Refer to Setting the Limits and Force on Step 4 2 4 3 and 4 4 Follow the instructions carefully and repeat the safety reverse test after any adjustment Remote Control Additional remotes...

Страница 28: ...25 5 Quick Setting Guide 5 1 Program your Opener Remote 5 2 To Erase all remote Control codes...

Страница 29: ...26 5 3 Unit Setting...

Страница 30: ...27...

Страница 31: ...28...

Страница 32: ...29...

Страница 33: ...you have any need to contact us the info below will help you get in touch TOPENS Website www topens com Contact Us E mail support topens com Kindly include your Product Model Purchasing Date Site Ord...

Отзывы: