The menu allows setting of the following functions.
1) Changing Masking Mode
Sets up masking (laser beam shut off) and change shut off directions.
Masking (Laser beam shutter) setting
Depending on the status of the location where the instruments are used, laser beam emission to
unnecessary direction can be shut off.
1
Press menu key to display the menu
screen.
The mask setting will be displayed on the
right in the upper side of the screen.
2
Use the arrow keys to position on the
Mask display and press the [ENT] key.
3
Select the direction you desire to mask
using the arrow keys.
Each press repeats mask activating/
releasing.
4
When desired masking is displayed, press the [ENT] key to finish.
Confirm the [OK] mark on the display
1) Changing Masking Mode 2) Changing rotary head speed
3) Setting channel 4) Sensitivity Level (LEVEL)
5) Safety Lock System (Height Alert) 6) Alarm Signal (COM)
The state when masking is not activated