Checking & Adjusting the Optical Plummet Telescope
P/N 31-050506-01
www.topconpositioning.com
A-7
2. Use the leveling screws to align the point and center mark,
correcting the other half of the displacement.
3. Rotate the instrument 180° or 200g around the vertical axis
once more and check the center mark (Figure A-2 on
page A-3). If it aligns to the point, further adjustment is not
required. Otherwise, repeat the adjustment.
TIP
TIP
First, loosen the capstan adjustment screw on the side to
which the center mark must be moved. Then tighten the
adjustment screw on the opposite side by an equal
amount, leaving the tension of the adjustment screws
unchanged. Revolve counter clockwise to loosen and
clockwise to tighten, but revolve as little as possible.