background image

10333349-01 Rev A 

10

 

 

TABLE 2 - Processor block diagram 

 

Supply voltage 

The CLOUDLYNK 10, properly connected, will be able to operate in accordance with the 
specification when the supply voltage will be in the range of 4,5 – 5,5 Vdc. 

The nominal supply voltage will be 5,0 Vdc (USB standard) 

Being all USB connectors intrinsically polarized, the power lines are not protected against the 
polarity inversion. 

 

Installation – setup 

CL10 installation 

With mounting arm for RAM 

1.

 

Remove the nuts from the RAM mount. 

2.

 

Place the CL10 arm over the RAM mount, align with the screws and replace the nuts. 

3.

 

Plug the CL10 into the USB port on the rear of the console. 

Содержание CL-10 3G

Страница 1: ...on Agriculture All contents in this manual are copyrighted by Topcon All rights reserved The information contained herein may not be used accessed copied stored displayed sold modified published or di...

Страница 2: ...apability to the host processor along with a multimode positioning system a GPS and telephone cell geo referencing and an hardware based highly secure encryption engine Furthermore 2 high speed USB po...

Страница 3: ...10333349 01 Rev A 3 Figure 1 Figure 2...

Страница 4: ...349 01 Rev A 4 Figure 3 Cover characteristics Back housing aluminum carrier Aluminum die cast Supporting the venting membrane and the label field Powder coating with structure semi gloss RAL 9006 Figu...

Страница 5: ...er plugs Supporting the internal antennas self sticking Supporting the external WiFi Antenna Supporting the M8 USB Main connector Plastic material color 9005 black Figure 5 Mass The CLOUDLYNK 10 total...

Страница 6: ...hile kept in an ambient of RH included in the range 5 85 non condensing A proper moisture coating could protect the CLOUDLINK 10 PCB the type and extent of the coating if any will be defined after the...

Страница 7: ...de Characteristics Current Consumption Modem 3G version SARA U201 U Blox Global coverage Approvals RED GCF CE FCC PTCRB Anatel Brazil AT T and other local approvals provider certifications RCM Austral...

Страница 8: ...n Chip KPN Verizon SIM on Chip for US Lock on local provider possible GPS EVA M8M uBLOX 72 channel u blox M8 engine GPS QZSS L1C A GLONASS L1OF BeiDou B1l Galileo E1B C SBAS L1C A WAAS EGNOS MSAS GAGA...

Страница 9: ...OAEP On Board Key Generation Updatable cryptographic profile True RNG random number generator according to AIS31 USB Hub note 1 USB2517 Microchip 1 upstream to 7 downstream USB Hub 2 User available d...

Страница 10: ...5 Vdc The nominal supply voltage will be 5 0 Vdc USB standard Being all USB connectors intrinsically polarized the power lines are not protected against the polarity inversion Installation setup CL10...

Страница 11: ...e CL10 are currently not used Product Warranty ELECTRONIC COMPONENTS TPA warrants that the electronic components manufactured by TPA shall be free of defects in materials and workmanship for a period...

Страница 12: ...may cause undesired operation 5 This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provi...

Страница 13: ...itation est autorisee aux deux conditions suivantes 1 L appareil ne doit pas produire de brouillage 2 L appareil doit accepter tout brouillage radioelectrique subi meme si le brouillage est susceptibl...

Отзывы: