Integral Promotional Serve Over - Akdeniz
Fans off during defrost
Parameter Definition
AKDENIZ M2
1
2 °C
0
-5 °C
+25 °C
12 °C
45 minutes
4 hours
+2 °C
+7 °C
SEt
Low Temperature Alarm
Temperature Set Point
DEFROST PARAMETERS
F3
FAN PARAMETERS
Time between Defrosts
Set Point Minimum
SET POINT
dt
AL
Display on LED
dl
Maximum Defrost Duration
dp
CONTROLLER PARAMETERS
rd
Control Differential
Set Point Maximum
r2
r1
End of Defrost Temperature
ALARM PARAMETERS
High Temperature Alarm
AH
Usage(continued)
As standard the case is supplied with a Carel PJEZ-S
full functional electronic controller, incorporating
an LED thermometer, which displays average case
operating temperature.
The controller is factory pre-set, but parameters may
be programmed as detailed below.
Reprogrammed parameters take immediate effect and
will be saved in the event of loss of power to the
controller.
Pressing 5 seconds to "UP" arrow supplies manual defrosting
when you determine icing up on the evaporator.
!!!
Содержание ISLA
Страница 5: ...Integral Promotional Serve Over Akdeniz 3 Sectional Drawings ...
Страница 14: ...Integral Promotional Serve Over Akdeniz Setting parameters on the PJEZ S Preliminary Configurations ...
Страница 21: ...Integral Promotional Serve Over Akdeniz 15 Troubleshooting ...
Страница 22: ...Integral Promotional Serve Over Akdeniz 16 Electrical Wiring Diagram for Akdeniz ...
Страница 23: ...Integral Promotional Serve Over Akdeniz 17 Declaration of Conformity ...
Страница 24: ...Integral Promotional Serve Over Akdeniz ...
Страница 25: ...Integral Promotional Serve Over Akdeniz ...