Top Gun ARC 145WR Скачать руководство пользователя страница 10

8

Fault

Resolution

Power indicator lit

Fan not running and no 

Welding input

A. Ensure power is turned off.

B. Ensure power is connected properly.

C. Heat sensor resistance incorrect or faulty. (24V relay has a fault)

D. Power source board (Board has problem, no DC537V output voltage.)

i. Silicon bridge circuit faulty or cable is loose.

ii. Part of the circuit board burnt.

iii. Check cable between switch and power source board. Power board between 

MOS board.

iv. Sub power source on control board faulty. Contact distributor or 

manufacturer.

Fan running and Fault 

indicator lit.

No output power.

A. Check all components are correctly connected.

B. Check if the output terminal has a broken circuit and poor connection.

C. Inverter circuit faulty;

1.  If Fault indicator lit: MOS board faulty, check and replace.

2. If Fault indicator not lit: 

i. Transformer on Middle Board faulty, measure primary inductance volume 

and Q volume of main transformer by inductance bridge.

Primary volume of parallel circuit, L=1.2-2.0MH, Q>40 if inductance volume 

and Q volume is low, replace it.

ii. Check the secondary rectifier tube on the transformer. If faulty replace.

iii. Feedback circuit in fault.

Power indicator not lit, 

fan not running and no 

welding output.

A.) Make sure the power switch is turned off.

B.) Make sure power supply and all cables are securely connected and power 

supply is working.

Power indicator lit, fan 

not running and no weld-

ing output.

A. Connected to incorrect power source has enabled machine protection circuit, 

connect to correct power supply and check machine for operation.

B. Input power not stable (input cable too small) or input cable incorrectly 

connected to power supply has caused protective circuit to be enabled. Check 

connections and turn off the machine for 5-10minutes. Turn the machine on and 

check for operation.

C. Turning the machine power switch ON and OFF too quickly has enabled the 

protection circuit. Turn the machine off for 5-10 minutes. Turn on and check for 

operation.

D. Power supply cables/plugs are loose. Turn Machine off and Check for proper 

connection of all power supply cables/plugs and check for operation.

Fixes and Faults

TROUBLESHOOTING

Содержание ARC 145WR

Страница 1: ...Manual Guide TOPGUNWELDING COM AU MMA STICK WELDER ARC 145WR ARC 186WR Manual Guide TOPGUNWELDING COM...

Страница 2: ......

Страница 3: ...MACHINE SPECIFICATIONS ARC WELDING TECHNIQUES FIXES AND FAULTS JOINT TYPES BASIC THEORY ACCESSORIES AND CONSUMABLES MACHINE BREAKDOWN INSTALLATION AND OPERATION PAGE 2 PAGE 4 PAGE 5 PAGE 6 PAGE 7 PAGE...

Страница 4: ...semi automatic or automatic wire welding eg MIG the wire wire reel drive roll housing and all metal parts touching the welding wire are electrically live Incorrectly installed or improperly grounded e...

Страница 5: ...s 5 Watch for fire and keep a fire extinguisher nearby 6 Be aware that welding on a ceiling floor bulk head or partition can cause a fire on the hidden side 7 Do not weld on closed containers such as...

Страница 6: ...Cycle Machine Weight Machine Dimensions mm Warranty Input Voltage V 240 A C 50 Hz 20 180 A 60 180A 100 160A 5 6 Kg 345x245x155 3 Years Frequency Hz Output Current Range A Rated Duty Cycle Machine Wei...

Страница 7: ...large irregular blobs The weld bead is flattened and spatter will increase A short arc is essential if a high quality weld is to be obtained although if it is too short there is the danger of it bein...

Страница 8: ...awing Connect the earth lead connector to the negative quick connection terminal and turn clockwise to tighten Connect the electrode clamp holder to the positive quick connection terminal and turn clo...

Страница 9: ...S BREAKDOWN 1 Main Board 2 Front Plastic Panel 3 Front Panel Socket 4 Main Control Board Set 5 Machine Cover 6 Handle 7 Cooling Fan 8 Back Plastic Panel 9 Inverter Main Transformer 10 Output Copper Co...

Страница 10: ...rcuit L 1 2 2 0MH Q 40 if inductance volume and Q volume is low replace it ii Check the secondary rectifier tube on the transformer If faulty replace iii Feedback circuit in fault Power indicator not...

Страница 11: ...ase contact the distributor or agent Fan running and Fault indicator is lit but no output current A Over current protection circuit enabled Turn off the machine and wait 5 10 minutes Once the Fault in...

Страница 12: ...clean and free of rust scale dirt grease etc Slag should be removed from oxy cut surfaces Typical joint designs are shown in Figure 6 10 The electrodes dealt with in this publication can be used in mo...

Страница 13: ...GP0525 CETG6013GP0532 316L 16 Stainless Steel 2 5mm 0 5kg pack 3 2mm 0 5kg pack CETG316L160525 CETG316L160532 312 16 Dissimilar Metals 2 5mm 0 5kg pack 3 2mm 0 5kg pack CETG312160525 CETG312160532 701...

Страница 14: ...ies Auto Darkening Welding Helmet Shadow TGHTSHAD Cold Carbon TGHTCCARB Bionix TGHTBION Envious TGHTENVI Robot TGHTROBO Rich Smoke TGHTRICH Welding Jackets Hi Vis Welding Jacket TGACWJHVL TGACWJHVXL T...

Страница 15: ...This page has been intentionally left blank...

Страница 16: ......

Отзывы: