background image

6.METHOD OF THE OPERATION

6.1.ARGON ARC WELDING(TIG)

6.1.1  CLEARING BEFORE WELDING

Tungsten argon  arc  welding  is  very  sensitive  to  surface   contamination of filled metal.  

Therefore  before  welding  is carried out,grease, paint and coating on the surface,lubricant for 

machining and oxidized film should be removed.

 

1.2 DC ARGON ARC WELDING 

    

.selector "10" onto the position " pulse off " ,Connecting the gas inlet pipe to inlet "21" of the

welding.

     

.Connecting gas  inlet  pipe  of  the  welding  torch  to  argon output of welder "17".

     

.Putting the aerial plug of the welding  torch  in  the  argon arc control socket "18".

     

.Testing gas: get the power of the welder ready and switch  on  the power "2", open  the 

argon

 bottle switch and switch on the  flow  meter, press the torch switch, select suitable argon flow.

    

. .Regulating the base current knob "13". Selecting  suitable welding current according to 

thickness of the workpiece  to  be  welded..  Selecting  suitable  current  down  slope  time  and  
after  flow  time according to the current.
 

Notice 1: 

The current indicating meter on the front panel  is used to display the preset output 

current level before welding, and actual output level while welding: A lit display indicates input 
power is turned on.
   

Notice 2: 

  When using 

 '

Adjustable foot control

 '

.regulating the  current with sole.  welding  current

 will increase gradually when you step at full tilt the '

Adjustable foot control 

 with sole.

    

. Tungsten electrode end is 2-3mm away from the  welding  workpiece. Press the torch 

switch,arc striking will occur.   
 

Notice: 

During welding, when the" 12. 2steps/4steps switch"on "2 steps", switch of the torch  

oo

workpiece

torch

21

argon

bottle

switch

flow meter

gas inlet pipe

20

24

23

22

7

8

4

9

10

11

13

3

5

6

15

15

16

17

18

16

1

12

19

26

TIG180D

Содержание TIG180D

Страница 1: ...THANKS FOR PURCHASING OUR PRODUCT ASSEMBLY AND OPERATING INSTRUCTIONS INVERTER DC TIG PULSE TIG DC MMA WELDING MACHINE be suitable for 1x220 240V...

Страница 2: ...E WHEN REPAIRING OR ADJUSTING Inspect before every use Only use identical replacement parl 10 FOLLOW ALL MANUFACTURER S RULES on operating switches and making adjustments 11 ALWAYS WEAR PROTECTIVE CLO...

Страница 3: ...welder has outstanding feature of minimum current The minimum current can be up to 5A Protection measures of the welder are perfect The welder is reliable light in weight and easy to use It is partic...

Страница 4: ...quipment and the persons the customer must correctly make grounding or protecting according to the power supply system using 4 mm 2 lead to connect the protection grounding of the welder d Welding ope...

Страница 5: ...k time on pulse freq down slope end current post flow 8 warning indicating light 9 indicating light of MMA Parameter Select function arcforce slector Hot start time hot start amp 10 Pulse on pulse off...

Страница 6: ...e argon flow Regulating the base current knob 13 Selecting suitable welding current according to thickness of the workpiece to be welded Selecting suitable current down slope time and after flow time...

Страница 7: ...ll the same as DC are welding 6 2 Hand welding with electrode selector 10 onto the position MMA Regulating Current Knob 3 to select right welding current select empiric formula I 40d d is dia of the e...

Страница 8: ...t connection butt connection and filling welding wire dia of welding wire mm welding current A Argon flow L min welding current argon flow L min DC positive connec tion 0 5 10 30 4 15 35 4 1 0 0 8 15...

Страница 9: ...e welding b Heating and cooling of each welding point is very fast Therefore the process is applicable for the workpiece with great difference of heat conductivity and thickness c Pulse arc can obtain...

Страница 10: ...TIC BLOCK DIAGRAM 10 TROUBLES AND PROBLEM SOLVING Input Rectifier Filter Inverse Circuit 25KHz output Rectifier Filter AC220 230 240V panel H F Control Circuit Trouble Causes Problem Solving Power lam...

Страница 11: ...ails 1 Replace torch switch 2 Regulating discharging interval to 0 8 1 0mm 3 Put torch tungsten electrode close to work piece 4 Replace high frequency arc generator Arc of argon welding is broken or t...

Страница 12: ...g No Test results of this welder fulfils_____________ _________technical requirements and its release from the works is granted Inspector_________ Date TIG180D Welding machine 1 Welding Holder 1 Groun...

Страница 13: ...electrically live parts or electrode with skin or wet clothing Insulate yourself from work and ground No toque las partes o los electrodos bajo carga con la piel o ropa moja da Aislese del trabajo y...

Страница 14: ...e Be und Entl ftung des Arbeitsplatzes Mantenha seu rosto da fuma a Use ventila o e exhaust o para remover fumo da zona respirat ria Turn power off before servicing Desconectar el cable de ali mentaci...

Отзывы: