FILTERS
There are filters underneath every fill opening of the reservoirs,
that prevents contamination from getting into the reservoir. There
is also a filter in front of every pump in the reservoir (not visible)
for the same reason. This filter can only be replaced by
refurbishment.
SAFETY INSTRUCTIONS
1.
Before making any modifications in your system, or
disconnecting the ECO-ClimaTEC, turn off the electric
power of the system.
2.
Always follow the instructions and regulations conform
this manual or more stricter local regulations if they apply.
TIPS
1.
If any doubts occur how to use the ECO-ClimaTEC
otherwise as listed in this manual, contact Top-Cool for
instructions or confirmation.
2.
If there is doubt about a (sufficient) flow, you can use a
flow switch, a flow meter or flow indicator (like a
propeller) in the flow to visually check if there is still a flow
in the system.
3.
You can use the ECO-ClimaTEC for cooling but also for
heating as main operating purpose!
4.
For a better performance of the ECO-ClimaTEC it is
recommended to cover the tubes between the ECO-
ClimaTEC and the radiator/fan combination with insulation
foam. It also recommended using tubes that are as short
as possible to reduce loss of energy.
5.
Make sure there are no kinks in the liquid tubes that can
block the liquid flow.
6.
To reach a high efficiency the temperature of the cooling
fluid that is leaving the radiator should maximal be 10°C
above the ambient temperature.