background image

 

confirm ,buzzer rings 1s,

TARGET

CALORIES 

  begins counting down,.TIME, DISTANCE ,WATTS, SPEED, RPM 

beigin to count by operation value(Fig 12) 

 

 

9.

 

TARGET HR

 

A

 

Press key to enter this mode, 

TARGET HEART RATE 

flashes and buzzer rings 1 second   

B

 

AGE continues to light on ,age value flashes and press UP or DOWN to set up AGE(Fig13) . Press ENTER to 
confirm ,buzzer rings for 1s,

TARGET HEART RATE

HEART RATE continues to light on,MAX HR continues to 

light on and shows heart beat at 65% and 85% .TIME

DISTANCE

CALORIES

WATTS

SPEED

RPM start to 

count by operation value 

 

C

 

When Hear beat drops to 65%, 

  and 65% value will light on , buzzer rings every 10s, till Heart rate 

reaches above 65%   

D

 

When Hear beat exceeds 85%, 

  and 85% value lights on , buzzer rings every 10s, till Heart rate drops 

below    85%   

 

E

 

When heart beat maintains 65%--85%, hear beat symbol flashes ,And it enters 65%-85% when it doesnot 
show MAX/65%/85% 

 

             

 

Fig13                               

12

  Press START one time despite any other keys , entering pulse mode. Within 30s, buzzer rings 0.5s every 

1s .When the system enters in PULSE mode , all display will save on the screen after 3s, light on every 4s( 3 
lights /1off).After 5minutes of pulsing , buzzer rings 2s to enter wake mode, press START to continue 
running 

 

13

30s after without single input, buzzer rings 1s to enter wake mode 

 

 

 
 
                 
 

Содержание RACE CROSS

Страница 1: ...Ed Rev INSTRUCTION 03 20 TOXPRFRACECRS 00...

Страница 2: ...mpact on the joints Lateral Handle C When standing on treadmill or losing balance you can hold it to stand firm when quick walking or running you can keep balance by it Side upper boards D When the us...

Страница 3: ...t fix the right pillar with Inner Hex Cylindrical Head Screws 4 M12 45 Washer 6 12 Spring pad 5 12 Then connect the Wire C bypass wire disc 03 to Reluctance shaft d Picture2 Picture 3 D Fixing the cen...

Страница 4: ...slightly curved the more toward the central handle the speed more faster more backward the speed more slower If the user feels that the running belt is suddenly subsided grasp both sides of the handl...

Страница 5: ...ill at the same time is forbidden Treadmill designed and produced only for simulation walking and running Any other purpose will be regarded as improper behavior and may cause danger Do not touch the...

Страница 6: ...l Adapter N Weight 195KG Max User Weight 180KG Noise Degree Below 80dB A Protection Level IP 20 Running Temperature From 5 C to 40 C Electrical insulation level II Level Product Dimension L W H 1680 9...

Страница 7: ...the floor condition isnot suitable to use wheel to move lifting and transporting equipment will be needed Warning You must be very careful when you move otherwise it will damage the stability of the e...

Страница 8: ...he label In order to ensure the equipment can be used safely it should be inspected every two weeks for product damage or wearing issue All operations of cleaning and maintenance should be carried out...

Страница 9: ...ps per second Stop pressing the process will stop 4 DOWN KEY A Each function can be set for TIME DISTANCE CAL and AGE after clicking DOWN KEY during display B Press DOWN KEY more than 1 second during...

Страница 10: ...WATTS SPEED RPM start counting by operation value Figure 3 C The heartbeat symbol flickers when heartbeat input and symbol flickers and displays the current heartbeat value Figure 4 Heartbeat input P...

Страница 11: ...also flashes synchronously This animation is still E C and D continue to repeat the cycle adding 1 to each cycle count until CYCLE TIME begins to count down 10 seconds after the 08 08WORK motion is d...

Страница 12: ...nning H press the STOP button or buzzer rings 1 second after the end TIME shows the total time DISTANCE shows the total distance CALORIES shows the total calorie consumption for 30 seconds WATT SPEED...

Страница 13: ...SPEED RPM exchanges the average and maximum values every five seconds K When there is heartbeat input the 85 and 65 heartbeat values are exchanged with the maximum value every five seconds but not dis...

Страница 14: ...operation value C When Hear beat drops to 65 and 65 value will light on buzzer rings every 10s till Heart rate reaches above 65 D When Hear beat exceeds 85 and 85 value lights on buzzer rings every 1...