![ToolPRO POWER CUT 25K Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/toolpro/power-cut-25k/power-cut-25k_instruction-manual_1127229009.webp)
TROUBLE SHOOTING
Breakdown and Solutions
No.
Breakdown
Analysis
Solutions
1
Indication Light is off
after turning on the
power supply.
The light is broken
Replace
Fuse is ruined.
Replace
No 240V Input Voltage
Get through 240V
Input cable
Power supply switch is
broken
Replace
Controlling board or cutter is
ruined
Examine and repair
2
Fan doesn’t work after
turning on the power
supply
Fan is ruined
Replace
Fan’s down-lead is broken
Examine and repair
Fan’s leaf is blocked
Clean the block
Transformer is ruined
Replace
3
Pressure lack Indication
Light is on
No input compressed air
Examine and repair
Air pressure valve is adjusted
to 0 or broken
Adjust or Replace
Gas circuit is blocked
Clean the block
Gas valve is ruined
Replace
4
No gas check function
Gas valve is ruined
Replace
Gas circuit is blocked
Clean the block
Gas check switch is ruined
Replace
Down-lead is broken
Examine and repair
5
Can’t cut or no high
frequency output
Discharge gap is too big
Adjust to suitable gap
High pressure mica capaci-
tance ruined
Replace
Pilot transformer is ruined
Replace
Main controlling board is
ruined
Examine and repair
Down-lead is broken
Examine and repair
6
Can’t cut or no current
output
Torch is broken
Examine and repair
Commutate module is
broken
Replace
AC contacting equipment is
broken
Replace
Cutting thickness mode
switch is broken
Replace
Main controlling board is
ruined
Examine and repair
Down-lead is broken
Examine and repair
7
No response after turn-
ing on the torch switch
Switch and down-lead are
broken
Examine and repair or
Replace
Switch board is broken
Examine and repair or
Replace
Main controlling board is
ruined
Examine and repair or
Replace
Transformer is ruined
Replace
Down-lead is broken
Examine and repair
8
No response after
turning on power supply
Lack of phase
Examine and repair
Power supply switch is
broken
Replace
Fuse is ruined
Replace
Transformer is broken
Replace
Main controlling board is
ruined
Examine and repair or
replace