8
9
COMPONENTS & CONTROLS (PIC.1)
1. Engine switch
2. Low oil alarm indicator (Red)
A. It will start flashing when the engine starts with
insufficient amount of engine oil.
B. It illuminates red indicating oil level below
the safe limit before the engine automatically
shuts down within 10 seconds.
3. Power indicator light (Green)
Will remain ON during operation. However, when the
green light starts flashing:
A. Interval Flash 1 time, low-voltage protection,
engine speed low.
B. Interval Flash 2 times, high temperature protection.
C. Interval Flash 3 times, overload protection, too
many loads.
D. Interval Flash 4 times, short-circuit protection.
The output power will be cut off should the generator is
experiencing any of the faults that are mentioned above.
Stop the engine to fix the issue before restarting the
engine.
4. Earth bolt point for earth lead
5. 5V USB socket
6. AC socket
7. Air filter connection screws
8. Recoil starter grip
9. Air filter cover
10. 12V DC cigarette lighter socket
11. Fuel tank
12. Fuel cap
13. Fuel valve
14. Muffler
15. Spark plug cap
16. Choke lever
17. DC circuit breaker
18. Oil filler cap
9
8
7
7
12
13
11
6
16
15
14
6
5
4
3
2
1
17
10
18
PIC. 1
Содержание 2200W
Страница 23: ...23 ...