background image

TROUBLESHOOTING GUIDE

The air compressor should be turned off and unplugged from the power source before any 

maintenance is performed as well as the air bled from the tank and the unit allowed time to 

cool. Personal injuries could occur from moving parts, electrical sources, compressed air, or hot 

surfaces.

Problem

Possible Correction

Air leaks at the check valve or 

at the pressure relief valve.

A defective check valve results in a constant air leak at the 

pressure release valve when there is pressure in the tank and 

the compressor is shut off. Drain the tank, then remove and 

clean or replace the check valve.

Air leaks between head and 

cylinder.

Be sure of proper torque on head bolts. If leak remains, contact 

a service technician.

Air leak from safety valve

Operate the safety valve manually by pulling on the ring. If the 

valve continues to leak when in the closed position, it should be 

replaced.

Pressure reading on the 

regulated pressure gauge 

drops when an accessory is 

used.

If there is an excessive amount of pressure drop when the 

accessory is used, replace the regulator.

NOTE:

Adjust the regulated pressure under flow conditions (while 

accessory is being used). It is normal for the gauge to show 

minimal pressure loss during initial use of the tool.

Excessive tank pressure.

Move the Auto-On/Off lever to the Off position. If the unit 

doesn’t shut off, unplug it from the power source and contact a 

service technician.

Motor will not start.

Make sure power cord is plugged in and the switch is on. 

Inspect for the proper size fuse in your circuit box. If the fuse 

was tripped reset it and restart the unit. If repeated tripping 

occurs, replace the check valve or contact your service 

technician.

Excessive moisture in the 

discharge air.

Remove the water in the tank by draining after each use. High 

humidity environments will cause excessive condensation. 

Utilize water filters on your air line.

NOTE:

Water condensation is not caused by compressor malfunction. 

Be sure the compressor’s air output is greater than your tool’s 

air consumption rate.

Air leaks from the tank body or 

tank welds.

Never drill into weld or otherwise modify the air tank or it will 

weaken. The tank can rupture or explode. Compressor cannot 

be repaired. Discontinue use of the air compressor.

7.

Содержание Platinum Series

Страница 1: ...OIL FREE AIR COMPRESSOR INSTRUCTION MANUAL Platinum Series 1 ...

Страница 2: ...Risk of Falling Operation of the air compressor should always be in a position that is stable Never use the air compressor on a rooftop or elevated position that could allow the unit to fall or be tipped over Use additional air hose for elevated jobs Risk from Flying Objects Always wear approved safety glasses with side shields when the air compressor is in use Turn off the air compressor and drai...

Страница 3: ...motor and also the cut in cut out pressure settings This switch serves as the Auto On Off positions for the unit 45 Air Intake Filter Provides clean air to the pump and must always be kept free of debris Check on a daily basis or before each use 38 Check Valve When the pump is not in operation the valve closes to retain air pressure inside the tank 60 Pressure Relief Valve The pressure relief valv...

Страница 4: ...Bolt 26 Right Crankcase 27 Protection Ring 28 Assembly Bolt 29 Assembly Bolt 30 Spring Washer 31 Stator 32 Assembly Nut 33 Rotor 34 Bearing 6203 2z 35 Adjusting Washer 36 Rubber Mount 37 Spring Washer 38 Air Filter 39 Elbow 40 Deflating Tap 41 Regulator 42 Outlet Pressure gauge 43 Tank Pressure gauge 44 Connector 45 Pressure Switch 46 Safety Valve 47 Handle 48 Tank 49 Wheel Nut 50 Wheel 51 Bolt Ax...

Страница 5: ...ir or replacement of the cord or plug is necessary do not connect the grounding wire to either flat blade terminal The wire with insula tion having an outer surface that is green with or with out yellow stripes is the grounding wire Check with a qualified electrician or serviceman if the grounding instructions are not completely understood or if in doubt as to whether the product is properly groun...

Страница 6: ...d upon the hours of operation and the working environment Air compressors used in an extremely dirty and or hostile environment will require a greater frequency of all maintenance checks Daily Shut Down Procedures 1 Set the Auto On Off lever to the Off position 2 Unplug the power cord from the receptacle 3 Set the outlet pressure to zero on the regulator 4 Remove any air tools or accessories 5 Ope...

Страница 7: ... when the accessory is used replace the regulator NOTE Adjust the regulated pressure under flow conditions while accessory is being used It is normal for the gauge to show minimal pressure loss during initial use of the tool Excessive tank pressure Move the Auto On Off lever to the Off position If the unit doesn t shut off unplug it from the power source and contact a service technician Motor will...

Отзывы: