Wire feeds, but shielding gas does not Flow
Possible causes and solutions
1.
Empty Gas cylinder:
Check gas cylinder.
2.
Nozzle plugged:
Clean nozzle. If damaged, replace.
3.
Regulator or cylinder valve closed:
Make sure both valves are adjusted properly.
4.
Gas line blocked:
Check external hose, and hose within Torch cable.
5.
Gas solenoid broken or not connected properly:
Have a qualified technician check/replace.
MAINTENANCE
WARNING! Make sure the Power Switch of the Plasma Cutter is in its “OFF”
position and that the tool is unplugged from the electrical outlet before performing
any inspection, maintenance, or cleaning procedures.
1. Before each use, inspect the general condition of the Welder. Check for loose cable
connections, misalignment or binding of the fan, cracked or broken parts, damaged
electrical wiring, and any other condition that may affect its safe operation. If abnormal
noise or vibration occurs, have the problem corrected before further use. Do not use
damaged equipment.
2. Periodically recheck all nuts, bolts, and screws for tightness.
3. Periodically blow the dust from the cooling vents with compressed air.
4. Verify that the cooling fan is operational before cutting.
5. If the unit repeatedly shuts down from thermal overload, stop all use. Have the welder
inspected and repaired by a qualified service technician.
6. Store the welder and accessories in a clean and dry location.
7. Periodically disassemble and clean the Torch Head components with steel wool.
Replace burnt, cracked, distorted, or coated components, Refer to the assembly
drawing on page 21.