10 seconds before turning off, a brief beep sounds and the indicator starts flashing. To 

extend the operating time, press either the temperature control or press the red button. The 

switch-off time is reset.
After switching off, the heater and pump are easily activated again by pressing the red 

button. Shortly after heating up, the soldering tool is again ready for use.

3.  Setting the temperature offset 

The temperature at the soldering tool’s exit point may be compromised by environmental 

conditions. In this case, the temperature displayed might differ from the actual temperature. 

The device is able to even up this difference in temperature by a corrective value (offset).
In order to determine the temperature difference, the temperature must be measured.
Determine the temperature by means of a thermometer with external sensor directly at the 

soldering tool’s exit port. Write down the measured value (T1).
Now read the actual temperature value on the soldering tool display (T2).
The difference of value T1 and T2 equals the offset value. Example: Measured temperature 

300 °C (T1), actual temperature shown 320 °C (T2). T1 - T2 = 300 °C - 320 °C = -20 °C.
To turn this function on, press and hold the red button. The display shows “- - -”. 
Set the calculated offset value with the “SET TEMP” controller. Release the red button. The 

value is stored and maintained also after turning the device off.

Notes on operation

  1.   Be careful when working with high temperatures!

 

   Never use the device in close proximity to inflammable gases, paper and other 

flammable materials! The hot air nozzle as well as the warmed up air are ex-

tremely hot and can lead to painful burns upon contact with them. Thus, never 

touch the hot air nozzle with your hands! Make sure that the hot air can never 

blow onto your skin! The white smoke at the beginning disappears shortly.

 

2.   After its use, the device must cool down completely!

 

   When you have switched off the device, it starts cooling down automatically by 

blowing cool air through the hose. Never pull the mains plug out of the socket 

during this phase but wait until this phase is completed!

 

3.   Use the device carefully - do not expose it to mechanical stress!

 

  The pipe in the hot air nozzle consists partly of fragile quartz glass.

 

4.   We strongly recommend to unplug the device from the mains voltage 

when it is not used for a longer period of time!

 

   There is a small amount of current even in electrical devices that are connected 

to the mains. For this reason, it is advisable to disconnect the device from the 

mains!

Unsoldering

1.  To melt the tin-solder, hold the hot air nozzle so that the nozzle adapter is positioned di-

rectly over the IC. (Direct contact between IC and adapter must absolutely be avoided!) The 

tin-solder starts melting due to the emitting hot air.

2.  Please remove the IC with pincers or tweezers as soon as the tin-solder is melted.
3.  After you have removed the IC you can remove the remaining tin-solder with an unsolder-

ing pump.

Soldering

1.  Apply e.g. the correct amount of SMD soldering paste and place the SMD piece on the 

board!

2.  Place the conductor board on a heating plate for pre-heating!
3.  Heat the soldering position evenly with hot air!
4.  Remove the remaining soldering material after the soldering process is finished!

  Note:

 

We recommend that you check the amount of soldering material sufficiently. Sol-

dering with hot air requires special concentration. Otherwise unwanted jumpers or 

over-sized soldering points could be the result!

Changing the fuse

  Disconnect the device from the mains each time you replace the fuse.

The device is protected with a fuse. Unscrew the protective cap at the backside of the housing. 

Remove the fuse. Replace it by a fuse of the same type (T3,15A 250 V, 5x20 mm). Screw the 

protective cap tightly.

Maintenance, care & disposal

The safety instructions below must be noted before the device is cleaned or maintained:

  Only a specialist who is familiar with the risks and relevant regulations may 

carry out repairs or open the housing.

 

 Before starting to clean or maintain, the device must be disconnected from 

the mains!

This device is maintenance-free. Clean the exterior of the device only with a soft, dry cloth or 

brush. Never use aggressive cleaning agents or chemical solutions since these might damage 

the surface of the casing or impair the operation.

Error message

The device monitors parameters and heating elements automatically. However, if a malfunction 

is detected, this will be shown as an error code on the display. Possible errors are:
Display “S-E”: 
Time-out at the temperature sensor, or the maximum temperature was exceeded. Reduce the 

set temperature and let the device cool off. Turn the device off and on again. If you still receive 

this error code, please contact Customer Service.
Display “H-E”:
Short circuit at the temperature sensor, or time-out at the heating element. Please contact 

Customer Service.
Display “C-E”:
Control loop shows zero crossing error. Turn the unit off and on. If you still receive this error 

code, please contact Customer Service.

Disposal

  Regarding our environment and to enable full recycling of the used raw material, the 

user is asked to bring the worn and defective devices to public collecting places for 

electric scrap.

  The symbol with the crossed out dust bin on wheels means that this product must be 

brought to a recycling site for electric scrap for a best possible recycling of the raw 

materials.

Technical data

Power supply ................................ 230 Volts / 50 Hz
Power consumption ...................... max. 550 Watts
Temperature range ....................... 100 °C to 480 °C
Air flow .......................................... max. 23 l / min.
Pump ............................................ Membrane pump
Noise level .................................... <52 dB(A)
Dimensions ................................... 245 x 187 x 135 mm
Weight .......................................... approx. 4 kg

Содержание AT 850D

Страница 1: ...rd gespeichert und bleibt auch nach dem Ausschalten erhalten Bedienungsanleitung Heißluft Löt Enlötsystem AT 850D Best Nr 588074 Bestimmungsgemäße Verwendung Dieses Heißluft Löt Enlötsystem eignet sich zum Löten und Entlöten von SMD und Micro Bauelementen DIP und Flat Pack IC s sowie zum Schrumpfen Erwärmen von Kunststoffen und Metallteilen zum Ablösen von Etiketten usw Die Temperatur und der Luft...

Страница 2: ...üse so dass sich der Düsenaufsatz z B direkt über dem IC befindet Ein direkter Kontakt von IC und Aufsatz muss unbedingt vermieden werden Durch die ausströmende Heißluft beginnt das Lötzinn zu schmelzen 2 Sobald das Lötzinn geschmolzen ist entfernen Sie bitte das IC mit einer Zange oder Pin zette 3 Nachdem Sie das IC entfernt haben können Sie das restliche Lötzinn mithilfe einer Ent lötsaugpumpe e...

Страница 3: ...Selecting the indication OFF deactivates this function Release the red button The value is stored and maintained after turning the device off Operating instructions Hot Air Soldering Unsoldering AT 850D Item no 588074 Intended use This hot air soldering unsoldering system is suitable for soldering and unsoldering SMD and micro components DIP and Flat Pack ICs as well as for shrinking and heating p...

Страница 4: ...le to disconnect the device from the mains Unsoldering 1 To melt the tin solder hold the hot air nozzle so that the nozzle adapter is positioned di rectly over the IC Direct contact between IC and adapter must absolutely be avoided The tin solder starts melting due to the emitting hot air 2 Please remove the IC with pincers or tweezers as soon as the tin solder is melted 3 After you have removed t...

Страница 5: ...ort Le produit ne doit pas être soumis à de fortes contraintes mécaniques Le produit ne doit pas être exposé à des températures extrêmes aux rayons di rects du soleil à de fortes vibrations ou à l humidité S assurer avant chaque utilisation que le produit ne présente aucun endom magement Au cas où vous constateriez un endommagement n utilisez plus le produit Débrancher le bloc d alimentation de la...

Страница 6: ... buse d air de sorte que l extension de la buse se trouve par ex directement au dessus de l IC circuit intégré Tout contact direct entre IC et extension doit impérativement être évité L air chaud soufflé commence à fondre l étain 2 Dès que l étain est fondu enlever l IC à l aide d une pince ou d une pincette 3 Après le retrait de l IC l étain résiduel peut être éliminé avec une pompe de débrasage ...

Страница 7: ...llen Het product niet blootstellen aan extreme temperaturen direct zonlicht sterke trillingen of vochtigheid Controleer het product vóór elk gebruik op beschadigingen Indien u beschadigin gen constateert dient u het product niet meer te gebruiken Koppel het los van de netspanning en haal de stekker uit de contactdoos Breng het product vervolgens naar een reparatiedienst Laat het apparaat uitsluite...

Страница 8: ...t smelten van het soldeertin houdt u de hete luchtnozzle zo dat het opzetstuk zich bijv direct boven de IC bevindt Een direct contact van IC en opzetstuk moet absoluut worden vermeden Door de uitstromende hete lucht begint het soldeertin te smelten 2 Zodra het soldeertin is gesmolten verwijdert u de IC met een tang of pincet 3 Nadat u de IC hebt verwijderd kunt u de overgebleven soldeertin met beh...

Отзывы: